CONMED LARGO HEX FLEX CANNULA WITH DISPOSABLE OBTURATOR, 8.0 X 85MM; ACCESSORIES,ARTHROSCOPIC Back to Search Results
Catalog Number C7480
Medical Device Problem Code Material Fragmentation (1261)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/27/2024
Type of Reportable Event Malfunction
Event or Problem Description
The sales representative reported on behalf of the customer that the c7480, hex flex cannula with disposable obturator, 8.0 x 85mm, was being used during an unknown procedure on (b)(6) 2024 when it was reported, ¿the tip of the cannula breaks, causing fragments of the product to fall into the patient's joint cavity.It took a long time for the surgeon to remove the fragment.".There was no report of injury, medical intervention, or hospitalization for the patient.This report is being raised due to the reported malfunction with potential for injury upon reoccurrence.
 
Additional Manufacturer Narrative
The reported device is being returned to conmed for evaluation.A supplemental and final report will be filed following the completion of the device evaluation and complaint investigation.We will continue to monitor for trends through the complaint system to assure patient safety.
 
Event or Problem Description
The sales representative reported on behalf of the customer that the c7480, hex flex cannula with disposable obturator, 8.0 x 85mm, was being used during an unknown procedure on 27feb24 when it was reported, ¿the tip of the cannula breaks, causing fragments of the product to fall into the patient's joint cavity.It took a long time for the surgeon to remove the fragment.".There was no report of injury, medical intervention, or hospitalization for the patient.This report is being raised due to the reported malfunction with potential for injury upon reoccurrence.
 
Additional Manufacturer Narrative
The device has not been returned for evaluation to date however, a photograph was provided.Review of the photograph however, does not show the tip of the cannula.The manufacturing documents from the device history record have been reviewed with special attention to the manufacturing and inspection of the product.The product released for distribution was found to have met all specifications prior to shipment.A 2 year lot history review shows a total of 2 devices for this lot number and failure mode.A two-year review of complaint history revealed there has been a total of 2 complaints, regarding 3 devices, for this device family and failure mode.During this same time frame 56,656 devices have been manufactured and shipped worldwide.Should all the complaint devices have been found confirmed for this reported failure, the rate of failure would be 0.00005.Per the instructions for use, the user is advised the following: 1.Remove items from the sterile package using aseptic techniques.2.Place the obturator into the hex flex cannula.If using the reusable obturator, place the hex flex assembly over a switching stick for entry into the joint.Reusable obturator sold separately.3.Verify that the hex key on the obturator is engaged with the cap.4.Slowly screw the cannula clockwise when inserting it into the joint.Once in the correct position the cannula will engage the capsule, muscle, skin, etc.This will prevent the cannula from backing out of the joint.5.To remove the cannula from the joint, slowly screw the cannula counterclockwise.6.Properly discard the hex flex cannula after use per facility guidelines.We will continue to monitor for trends through the complaint system to assure patient safety.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HEX FLEX CANNULA WITH DISPOSABLE OBTURATOR, 8.0 X 85MM
Common Device Name
ACCESSORIES,ARTHROSCOPIC
Manufacturer (Section D)
CONMED LARGO
11311 concept blvd
largo FL 33773
Manufacturer (Section G)
CONMED LARGO
11311 concept blvd
largo FL 33773
Manufacturer Contact
john berga
11311 concept blvd
largo, FL 33773
7273995358
MDR Report Key18911338
Report Number1017294-2024-00029
Device Sequence Number20575649
Product Code NBH
UDI-Device Identifier10845854018408
UDI-Public(01)10845854018408(17)280828(10)1330160
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 04/30/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue NumberC7480
Device Lot Number1330160
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/27/2024
Supplement Date Received by Manufacturer04/16/2024
Initial Report FDA Received Date03/15/2024
Supplement Report FDA Received Date04/30/2024
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured08/30/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Patient Sequence Number1
Patient SexUnknown
Patient EthnicityNon Hispanic
-
-