EXACTECH, INC. EQUINOXE, HUMERAL STEM PRIMARY, PRESS FIT 11MM; PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED
|
Back to Search Results |
|
| Catalog Number |
300-01-11 |
| Medical Device Problem Codes |
Adverse Event Without Identified Device or Use Problem (2993); Insufficient Device Problem Information (3190)
|
| Health Effect - Clinical Codes |
Bone Fracture(s) (1870); Limb Fracture (4518)
|
| Date of Event |
01/17/2024
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
(d10) concomitant device(s): 320-36-03 - 145-deg pe 36mm hum liner +2.5: (b)(6) ; 320-10-00 - equinoxe reverse tray adapter plate tray +0: (b)(6) ; 320-31-36 - glenosphere, 36mm: (b)(6) ; 320-35-03 - small posterior augment glenoid plate, left: (b)(6) ; 315-35-00 - glnd kwire: (b)(6) ; 319-01-32 - steinmann pin sterile 3.2mm x 178mm: (b)(6) ; 320-15-05 - eq rev locking screw: (b)(6) ; 320-20-00 - eq reverse torque defining screw kit: (b)(6); 320-20-30 - eq rev compress screw lck cap kit, 4.5 x 30mm: (b)(6); 320-20-30 - eq rev compress screw lck cap kit, 4.5 x 30mm: (b)(6); 320-20-34 - eq rev compress screw lck cap kit, 4.5 x 34mm: (b)(6); 320-20-38 - eq rev compress screw lck cap kit, 4.5 x 38mm: (b)(6); 521-78-32 - threaded pin size 3.0 collarless 2pk: (b)(6); 531-78-20 - shouldr gps hex pins kit: (b)(6).(h3) pending evaluation.
|
| |
|
Event or Problem Description
|
|
As reported by the equinoxe shoulder study, the 64-year-old male patient had a left tsa on (b)(6) 2024.The patient presented with a humeral fracture, intra-operatively on (b)(6)2024.Greater tuberosity fracture during the case.Bone was extremely osteoporotic.Had to use standard and cemented stem and convert to rtsa due to osteoporosis.The outcome of this event is considered continuing and the action taken was other - cerclage sutures around tuberosity at surgery.The case report form indicates that this event is definitely not related to the device and unlikely related to the procedure.This event report was received through clinical data collection activities and no device return is anticipated.
|
| |
|
Additional Manufacturer Narrative
|
|
The reason for the intraoperative bone fracture reported cannot be conclusively determined but may be related to a patient condition or high forces during broaching, reaming, exposure, or retraction.The patient had severe osteoporosis.However, this cannot be confirmed based on the information provided.H6: corrected health effect, medical device, component, and investigation clinical codes.
|
| |
|