| Catalog Number |
DWF364B |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Code |
Bone Fracture(s) (1870)
|
| Date of Event |
09/01/2023
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
In the tornier shoulder outcomes study, a traumatic acromial fracture occurred postoperatively.The adverse event resolved without sequelae.It was assessed as not related to the study device or the surgical procedure.An update noted that no action was taken, and no treatment was administered.During the visit, glenoid notching was observed, with the notch extending to the lower screw and glenoid lucencies involving the baseplate (superior or inferior).
|
| |
|
Additional Manufacturer Narrative
|
|
Based on the available information the device will not be returned therefore an evaluation of the device cannot be performed.A review of the device history is not possible because the lot number was not communicated.Should additional information become available, it will be provided on a supplemental report.H3 other text : device disposition unknown.
|
| |
|
Additional Manufacturer Narrative
|
|
Correction: g1 manufacturing site for devices.The reported event was not since the device was not returned for evaluation and no other evidences were provided.A device inspection was not possible since the affected device was not returned for investigation (remained implanted).The opinion of the medical expert was requested on this case despite the limited information provided, and stated as following: "the high age of the patient and a trauma are sufficient to fracture an acromion.The fact that it healed without intervention shows there is not an abnormal stress on the acromion.The radiographic finding of notching, involving the inferior peripheral screw may be caused by several factors (glenoid placement, nsa angle of the humeral component, and individual shoulder use by the patient).Without any further information, this radiographic finding cannot be assessed".A review of the device history was not possible because the lot number was not communicated.No corrective actions are required at this time.A review of the labeling did not indicate any abnormalities.Indications of material, manufacturing, or design related problems were unable to be identified as the lot number was not communicated.More detailed information about the complaint event as well as the affected device must be available in order to determine the root cause of the complaint event.If any additional information is provided, the investigation will be reassessed.
|
| |
|
Event or Problem Description
|
|
In the tornier shoulder outcomes study, a traumatic acromial fracture occurred postoperatively.The adverse event resolved without sequelae.It was assessed as not related to the study device or the surgical procedure.An update noted that no action was taken, and no treatment was administered.During the visit, glenoid notching was observed, with the notch extending to the lower screw and glenoid lucencies involving the baseplate (superior or inferior).
|
| |
|