EXACTECH, INC. VANTAGE TOTAL ANKLE SYSTEM; PROSTHESIS, ANKLE, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER
|
Back to Search Results |
|
| Model Number |
TIBIAL PLATE FB SZ 4 LT |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Pain (1994); Implant Pain (4561)
|
| Date of Event |
06/16/2023
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
As reported by the exactech vantage total ankle study, approximately 2.5 years post initial left taa, the 72 y/o male patient returned for pain below taa.The surgeon determined there is irregularity in the subtalar joint.Patient was given injection steroid into subtalar joint.Then, on (b)(6) 2023, follow-up from his sinus tarsi injection on the left ankle.The patient states that he did not get any relief even temporarily with the shot.The patient is mostly tender over the posterior tibial tendon.Referral to another surgeon for consideration of opening debridement and fdl tendon transfer.On (b)(6) 2023, the patient was there for follow-up.Patient has tried pt/hep.Pain worsening.Isolated to the posteromedial ankle.Has left posterior tibial tendinitis/partial tearing in the setting of prior taa.The event was resolved with patient having a revision on (b)(6) 2024.Per clinical report, the reported event is definitely not related to the device but possibly related to the procedure.
|
| |
|
Additional Manufacturer Narrative
|
|
Section d10: concomitant products: tibial insert fb sz 2 lt 12mm (cat# 350-21-62 / serial# (b)(6)).Additional information, including the product investigation, will be submitted within 30 days of receipt.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay corrected/ additional information.The following sections were corrected/added: b5, d4 (remove all data from initial report - catalog number unknown) d6b (remove date), g4, h4 (remove date) h6: clinical code, impact code, component code, type of investigation, investigation findings and investigation conclusions.The reason for the clinical symptom of pain reported cannot be conclusively determined and the event cannot be confirmed because the devices were not returned for evaluation, and relevant patient information, images, and radiographs were not provided.Should additional relevant information be obtained, a follow-up mdr will be submitted accordingly.
|
| |
|
Event or Problem Description
|
|
As reported by the exactech vantage total ankle study, approximately 2.5 years post initial left taa, the male patient returned for pain below taa.The surgeon determined there is irregularity in the subtalar joint.Patient was given injection steroid into subtalar joint.Then a follow-up from his sinus tarsi injection on the left ankle.The patient states that he did not get any relief even temporarily with the shot.The patient is mostly tender over the posterior tibial tendon.Referral to another surgeon for consideration of opening debridement and fdl tendon transfer.The patient was there for follow-up.Patient has tried pt/hep.Pain worsening.Isolated to the posteromedial ankle.Has left posterior tibial tendinitis/partial tearing in the setting of prior taa.The event was resolved with patient having a revision.Per clinical report, the reported event is definitely not related to the device but possibly related to the procedure.
|
| |
|
Search Alerts/Recalls
|
|
|