• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: CORDIS US CORP. INFINITI; CATHETER, INTRAVASCULAR, DIAGNOSTIC

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

CORDIS US CORP. INFINITI; CATHETER, INTRAVASCULAR, DIAGNOSTIC Back to Search Results
Catalog Number 538493
Medical Device Problem Code Detachment of Device or Device Component (2907)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/13/2024
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The device was received for analysis, but the engineering report is not yet available.Additional information is pending and will be submitted within 30 days upon receipt.
 
Event or Problem Description
As reported, a 4f infiniti diagnostic catheter separated in two pieces.The device was broken near the hub.The broken segment was still outside the patient and was retrieved.The entire product was able to be removed with nothing left behind.Another infiniti catheter was used to get the diagnostic heart catheterization procedure completed.There was no reported patient injury.It was during the second injection.A 4f non-cordis sheath was used.There were no anomalies noted when the product was removed from the package.The product was stored, handled, inspected, and prepped according to the instructions for use (fu).The target lesion was reported to be the left main coronary artery (lca).Lesion calcification is unknown; there was no vessel tortuosity and the percentage stenosis is unknown.The device was not used for a chronic total occlusion (cto).There was no unusual force necessary during use of the device and no resistance/ friction experienced during any part of the procedure.There was no resistance met while advancing the device.Excessive torquing was not required.The tip was visible on fluoroscopy throughout the procedure.The device was returned for evaluation.
 
Additional Manufacturer Narrative
As reported, a 4f infiniti diagnostic catheter separated in two pieces.The device was broken near the hub.The broken segment was still outside the patient and was retrieved.The entire product was able to be removed with nothing left behind.Another infiniti catheter was used to get the diagnostic heart catheterization procedure completed.There was no reported patient injury.It was during the second injection.A 4f non-cordis sheath was used.There were no anomalies noted when the product was removed from the package.The product was stored, handled, inspected, and prepped according to the instructions for use (fu).The target lesion was reported to be the left main coronary artery (lca).Lesion calcification is unknown; there was no vessel tortuosity, and the percentage stenosis is unknown.The device was not used for a chronic total occlusion (cto).There was no unusual force necessary during use of the device and no resistance/ friction experienced during any part of the procedure.There was no resistance met while advancing the device.Excessive torquing was not required.The tip was visible on fluoroscopy throughout the procedure.A non-sterile unit of ¿cath mpac inf 4f jr4/jl4/pig¿ was received for analysis.During visual inspection, the unit was noted to be separated in two pieces, and both segments were returned.The separation is located inside the strain relief approximately 100 cm from the distal tip.Inner diameter (id) and outer diameter (od) measurements were taken near the damages and were found within specification.Sem analysis was not performed because the damages associated with the separation are visible with the magnification obtained with a vision system.The separated edges were inspected with the vision system and elongations, diameter reduction, and plastic deformation was observed.No damages or anomalies were observed on the strain relief.The reported ¿catheter (body/shaft) ~ separated¿ was confirmed.The unit was returned separated in two pieces.The exact cause of this damage could not be conclusively determined during the analysis however, the characteristics found on the materials of the unit are commonly associated with separations caused by material tensile/twist overload.Therefore, it is assumed that the material was induced to a tensile/twist forces that exceeded the material yield strength prior to the separation.Procedural and/or handling factors may have contributed to the failure.Users are trained to inspect for signs of damage prior to and during use.Any product with damage is not to be used.Information for safety is provided in the products labeling with the intent to make the user aware of the risks.According to the instructions for use (ifu), although not intended as a mitigation of risk, ¿do not use if package is open or damaged.Treat all 4f (1.35 mm) catheters and smaller french sizes with ultimate care.The performance of these products may be impaired if not properly and cautiously handled during unpacking and preparation.¿ based on the available information, there is no indication that the event is related to the device design or manufacturing process.Therefore, no preventive or corrective actions will be taken at this time.
 
Additional Manufacturer Narrative
After further review, section d.4 primary unique device identification (udi) number has been corrected accordingly.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INFINITI
Common Device Name
CATHETER, INTRAVASCULAR, DIAGNOSTIC
Manufacturer (Section D)
CORDIS US CORP.
14201 nw 60th avenue
miami lakes, florida 33014
Manufacturer (Section G)
CORDIS US CORP.
14201 nw 60th avenue
miami lakes, florida 33014
Manufacturer Contact
karla castro
santiago troncoso 808
juarez, chihuahua 
7863138372
MDR Report Key18992822
Report Number9616099-2024-00092
Device Sequence Number3037725
Product Code DQO
UDI-Device Identifier10705032014953
UDI-Public(01)10705032014953(17)271231(10)18271174
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
K862244
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 08/26/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number538493
Device Lot Number18271174
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/22/2024
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/13/2024
Supplement Date Received by Manufacturer05/31/2024
08/26/2024
Initial Report FDA Received Date03/28/2024
Supplement Report FDA Received Date06/06/2024
08/26/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured01/05/2024
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
HEART CATH WITH 4 F TERUMO SHEATH
Patient Age60 YR
Patient SexMale
Patient Weight94 KG
-
-