C.R. BARD, INC. (BASD) -3006260740 POWERPICC SOLO2 CATHETER WITH SHERLOCK 3CG TIP POSITIONING SYSTEM; CATHETER,INTRAVASCULAR,THERAPEUTIC,LONG-TERM GREATER THAN 30 DAYS
|
Back to Search Results |
|
| Model Number |
N/A |
| Medical Device Problem Code |
Fluid/Blood Leak (1250)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
03/09/2024
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
(b)(6).Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The manufacturer has received the sample and will evaluate.Results are expected soon.
|
| |
|
Event or Problem Description
|
|
It was reported, ¿picc inserted (b)(6) 2024.Started leaking on friday, (b)(6) 2024, and was removed saturday, (b)(6) 2024.Crack noted in line at the 4mm mark and was difficult to remove.No ill effects to patient, new picc inserted (b)(6) 2024.¿ no other information was provided.
|
| |
|
Event or Problem Description
|
|
It was reported, ¿picc inserted (b)(6) 2024.Started leaking on friday, (b)(6) 2024, and was removed saturday, (b)(6) 2024.Crack noted in line at the 4mm mark and was difficult to remove.No ill effects to patient, new picc inserted (b)(6) 2024.¿ no other information was provided.
|
| |
|
Additional Manufacturer Narrative
|
|
Section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The complaint of a leak is confirmed and was determined to be use related.One 4fr sl powerpicc solo catheter was returned for evaluation.The investigation findings are consistent with damage accumulated through flexural fatigue.Flexural fatigue occurs due to cyclic kinking of the catheter tube in which physiological, placement, usage, and mechanical factors may gradually form a crack(s) in the catheter.The returned product sample was evaluated and a split was observed at the 4cm mark on the catheter body.The catheter split contained physical features associated with material fatigue, and the characteristics observed which supported this type of failure included: damage which was circumferentially aligned fracture edges which were rounded and polished due to repeated material wear overall elliptical shape to the fracture cross-section (a result of repeated kinking of the tubing) an examination of the catheter structure revealed no potential damage/defect related to manufacture of the product.The damage location suggested that catheter securement, access and maintenance techniques may have contributed.This complaint will be recorded for future trending and monitoring purposes.
|
| |
|
Search Alerts/Recalls
|
|
|