Model Number 39347-120470
Medical Device Problem Code Material Rupture (1546)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/12/2024
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that balloon rupture occurred.A 12.0mm x 40mm x 75cm athletis pta balloon dilatation catheter was advanced for dilatation.However, during inflation, it was noted that balloon ruptured before reaching rated burst pressure.The procedure was completed with another of the same device.No patient complications were reported.
 
Additional Manufacturer Narrative
Device evaluated by mfr: the device was returned for evaluation.A visual examination identified that the balloon was not folded, which indicates that the device was subjected to positive pressure.A leak test was carried out and the balloon was inflated to its rated burst pressure for 30 seconds using deionizes water and digital timer without issue.A vacuum was then applied.The inflation device was verified at 20 atmospheres, before and after use with calibrated pressure gauge.This inflation to rate of burst pressure was repeated three times with no leaks or drop in pressure noted.No issues were identified with balloon inflation or the balloon material.As per specification, the rated burst pressure for this device is 20 atmospheres.No issues were noted with the tip of the device.A visual examination found no issue with the markerbands.A visual and tactile examination found that the shaft was kinked at approximately 330mm distal of the strain relief.This type of damage is consistent with excessive force being applied to the device.No other issues were identified during the product analysis.
 
Event or Problem Description
It was reported that balloon rupture occurred.A 12.0mm x 40mm x 75cm athletis pta balloon dilatation catheter was advanced for dilatation.However, during inflation, it was noted that balloon ruptured before reaching rated burst pressure.The procedure was completed with another of the same device.No patient complications were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ATHLETIS PTA BALLOON DILATATION CATHETER
Common Device Name
CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
ballybrit business park
galway
EI  
Manufacturer Contact
rachel shields
4100 hamline ave n
arden hills, MN 55112
6512422111
MDR Report Key19046319
Report Number2124215-2024-16267
Device Sequence Number7242219
Product Code DQY
UDI-Device Identifier08714729974260
UDI-Public08714729974260
Combination Product (Y/N)N
Initial Reporter CountryKS
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,Company Representative,Distributor
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 05/07/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date05/12/2025
Device Model Number39347-120470
Device Catalogue Number39347-120470
Device Lot Number0029395792
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 03/12/2024
Supplement Date Received by Manufacturer04/16/2024
Initial Report FDA Received Date04/04/2024
Supplement Report FDA Received Date05/07/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured05/13/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-