Catalog Number DWD181
Medical Device Problem Code Unstable (1667)
Health Effect - Clinical Codes Loss of Range of Motion (2032); Discomfort (2330); Joint Laxity (4526)
Date of Event 03/13/2024
Type of Reportable Event Serious Injury
Event or Problem Description
As reported: "primary reverse shoulder arthroplasty, (b)(6) 2023.Patient complained of occasional instability, discomfort on movement, of this shoulder joint, over many months.Surgeon concluded, due to patient undergoing multiple operations on this shoulder, including cuff repair, that the patient has a soft tissue envelop instability.Decision made by surgeon to increase glenosphere size, and implant a more constrained poly liner.This was performed, and range of motion on reduction was acceptable, and joint found to be stable.All other primary implants left insitu.Hence, only 3 x prosthesis exchanged - reverse tray, poly insert and glenosphere.Shoulder joint stable at conclusion of procedure.".
 
Additional Manufacturer Narrative
Based on the available information the device will not be returned therefore an evaluation of the device cannot be performed.Should additional information become available, it will be provided in a supplemental report.
 
Additional Manufacturer Narrative
The reported event could be confirmed, bases on the evaluation done by hcp on provided x-ray images.The device inspection was not possible as the product was not returned for investigation.A review of the device history for the reported lot did not indicate any abnormalities.No corrective actions are required at this time.No indications of material, design & manufacturing related problems were found during the investigation.A review of the labeling did not indicate any abnormalities.However, on the available x-rays medical opinion was sought from an experienced independent medical expert as below, ¿the images show an inferior subluxation of the humerus in relation to the glenosphere.This is indeed a sign of insufficient soft tissue tension and joint instability.Other than that, all implant components are intact and the humeral stem and glenoid baseplate are well-fixated to the bone¿ based on investigation, the root cause was attributed to a patient related issue.The failure was caused due to insufficient soft tissue tension.If device is returned or any further information is provided, the investigation report will be reassessed.
 
Event or Problem Description
As reported: "primary reverse shoulder arthroplasty, (b)(6) 2023.Patient complained of occasional instability, discomfort on movement, of this shoulder joint, over many months.Surgeon concluded, due to patient undergoing multiple operations on this shoulder, including cuff repair, that the patient has a soft tissue envelop instability.Decision made by surgeon to increase glenosphere size, and implant a more constrained poly liner.This was performed, and range of motion on reduction was acceptable, and joint found to be stable.All other primary implants left insitu.Hence, only 3 x prosthesis exchanged - reverse tray, poly insert and glenosphere.Shoulder joint stable at conclusion of procedure.".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AEQUALIS REVERSED GLENOSPHERE 10 DG TILTED 36MM X 25MM
Common Device Name
SHOULDER PROSTHESIS, REVERSE CONFIGURATION
Manufacturer (Section D)
TORNIER S.A.S.
161 rue lavoisier
montbonnot saint-martin 38330
FR  38330
Manufacturer (Section G)
TORNIER S.A.S.
161 rue lavoisier
montbonnot saint-martin 38330
FR   38330
Manufacturer Contact
anna jusinski
325 corporate drive
mahwah, NJ 07430
2018315000
MDR Report Key19076079
Report Number3000931034-2024-00202
Device Sequence Number15145961
Product Code PHX
UDI-Device Identifier03700386935831
UDI-Public03700386935831
Combination Product (Y/N)N
Initial Reporter CountryAS
PMA/510(K) Number
K081059
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2023
Device Explanted Year2024
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 06/13/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Lay User/Patient
Device Catalogue NumberDWD181
Device Lot Number0610AX
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 03/13/2024
Supplement Date Received by Manufacturer05/15/2024
Initial Report FDA Received Date04/09/2024
Supplement Report FDA Received Date06/13/2024
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured05/12/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age66 YR
Patient SexFemale
-
-