| Model Number |
OJR416 |
| Medical Device Problem Codes |
Break (1069); Detachment of Device or Device Component (2907)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
(b)(4).Fisher and paykel healthcare (f&p) is in the process of completing our investigation.We will provide a follow-up report upon completion of our investigation.
|
| |
|
Event or Problem Description
|
|
A third-party vendor reported on behalf of a healthcare facility in (b)(6) via a fisher and paykel (f&p) healthcare representative that the tubing of an ojr416 optiflow junior 2 nasal cannula was detached from the cannula tube joint while being used on a patient.There were no reported patient consequences.
|
| |
|
Additional Manufacturer Narrative
|
|
(b)(4).The optiflow junior nasal cannula is designed specifically for the delicate anatomical features and flow requirements of neonatal and pediatric patients.It features adhesive pads (wagglepads) to maintain cannula stability on the patient's cheeks, soft-touch nasal prongs, and breathable kink-proof, and crush-resistant flexi tubing.Method: the complaint 2 x ojr416 optiflow junior 2 nasal cannula were returned to fisher and paykel (f&p) healthcare in new zealand for evaluation where it was inspected by a trained f&p technician.Results: visual inspection of the one of the returned devices revealed that the tubing was detached from the cannula tube joint.It was also revealed that a small amount of glue was observed inside the cannula joint and no glue residue was observed on the end tubing.The end of the tubing appeared to be cut off roughly.Conclusion: we are unable to determine the cause of the reported event.However, it is most likely caused by the tubing being inadvertently pulled or cut by a sharp object.All optiflow junior cannulas are 100% leak and occlusion tested after final assembly and any cannula that fails is discarded.Samples are also taken and pull tested to check the tube tensile strength and the glue joint strength at the cannula/ tube joint, as well as the swivel grip joint.The subject cannula would have met the required specification at the time of production.The user instructions illustrate in pictorial format the correct set-up and proper use of the optiflow junior 2 nasal cannula.They also state the following: appropriate patient monitoring (e.G.Oxygen saturation) must be used at all times.Failure to monitor the patient (e.G.In the event of an interruption to gas flow) may result in serious harm or death.Do not wrap, insulate, stretch or crush the tubing as this may impair the performance of this product or compromise safety including potentially causing patient harm).Ensure all connections are secure during use.Check the cannula is undamaged and that the flow path is maintained.Under excessive load, the cannula may disconnect to prevent forces being transferred to the patient.Ensure the patient does not lie on the tubing a this may apply pressure to the patient's ears or face.Failure to apply and use this product within the directions, transport, storage and operating conditions specified in the labelling and user instructions may impair performance of this product or compromise safety (including potentially causing serious patient harm.).
|
| |
|
Event or Problem Description
|
|
A third-party vendor reported on behalf of a healthcare facility in idaho via a fisher and paykel (f&p) healthcare representative that the tubing of an ojr416 optiflow junior 2 nasal cannula was detached from the cannula tube joint while being used on a patient.There were no reported patient consequences.
|
| |
|