Catalog Number AK-05503-L
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/23/2024
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).
 
Event or Problem Description
It was reported "end of catheter broke off and was left in patient upon removal.An xray came back negative when staff inspected for remaining catheter.Patient discharged." no patient harm or injury.The patient's current condition is reported as "fine".
 
Additional Manufacturer Narrative
Qn# (b)(4).The customer reported the catheter broke during removal.The customer returned one snaplock assembly and an epidural catheter.The returned components were received connected together.Visual examination of the returned snaplock assembly revealed the snaplock appears typical with no observed defects or anomalies.Visual examination of the returned catheter revealed the extrusion and coil wire are stretched at the distal end with the coil wire extending approximately 17cm beyond the extrusion.Both the proximal and distal ends of the returned catheter appear to be intact.The catheter appears to have been used as biological material can be seen between the inner coils and adhesive material can be seen on the outer extrusion.No other defects or anomalies were observed.A dimensional inspection was performed on the catheter.The returned catheter extrusion measures approximately 90.9.None of the catheter appears to be missing.The catheter is within specification of 88.5-91.5 cm per graphic.A device history record review was performed on the epidural catheter with no relevant findings.The ifu for this kit warns the user, "never tug or quickly pull on catheter during removal from patient to reduce risk of catheter breakage.Do not apply additional tension on the catheter if catheter begins to stretch excessively.Reposition patient to open the vertebral interspaces and re-attempt removal if resistance is encountered or if catheter stretches excessively during removal." the reported complaint of catheter breaking during removal was confirmed based upon the sample received.Visual examination of the returned sample revealed extrusion and coil wire were stretched at the distal end with the coil wire extending approximately 17cm beyond the extrusion.None of the catheter appeared to be missing.The ifu for this product warns the user to never tug or quickly pull on catheter during removal from patient to reduce risk of catheter breakage.Therefore, based upon the condition of the sample received , unintentional user error caused or contributed to this event.No further action is required at this time.
 
Event or Problem Description
It was reported "end of catheter broke off and was left in patient upon removal.An xray came back negative when staff inspected for remaining catheter.Patient discharged." no patient harm or injury.The patient's current condition is reported as "fine.".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARROW EPIDURAL CATHETERIZATION KIT
Common Device Name
ANESTHESIA CONDUCTION CATHETER
Manufacturer (Section D)
ARROW INTERNATIONAL LLC
morrisville NC
Manufacturer (Section G)
ARROW INTERNATIONAL DE MEXICO S.A. DE C.V.
ave. washington 3701
colonia panamericana, chihuahua
chihuahua 31200
MX   31200
Manufacturer Contact
katharine tarpley
3015 carrington mill blvd
morrisville, NC 27560
MDR Report Key19077960
Report Number9680794-2024-00327
Device Sequence Number5897338
Product Code BSO
UDI-Device Identifier70801902005150
UDI-Public70801902005150
Combination Product (Y/N)N
Initial Reporter StateCA
Initial Reporter CountryUS
PMA/510(K) Number
K140110
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source User Facility,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 03/20/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Expiration Date04/30/2025
Device Catalogue NumberAK-05503-L
Device Lot Number33F23H0866
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/28/2024
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/20/2024
Supplement Date Received by Manufacturer04/16/2024
Initial Report FDA Received Date04/10/2024
Supplement Report FDA Received Date04/30/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured09/11/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
NONE REPORTED; NONE REPORTED
Patient SexFemale
-
-