SYNTHES GMBH 2.4/2.7MM VA-LCP T-FUSION PL 3 HOLE HEAD/EXTRA LONG; PLATE, FIXATION, BONE
|
Back to Search Results |
|
| Catalog Number |
02.211.265 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Pain (1994); Nonunion/Delayed-union Bone Fracture (2369); Swelling/ Edema (4577)
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.H10 additional narrative: d2: additional procode: hwc.D9: complainant part is not expected to be returned for manufacturer review/investigation.E3: initial reporter is a synthes employee.H3, h4, h6: without a lot number the device history records review could not be completed.Product was not returned.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Event or Problem Description
|
|
In collaboration with depuy synthes, dr., together with cleveland clinic foundation (ccf) database designers, program managers, research assistants, and biostatisticians, has developed a report that summarizes safety and effectiveness data on 100 patients who underwent foot surgery at ccf between 2008 and 2023 utilizing depuy synthes (dps) foot plates.Some patients were noted to have adjunctive depuy synthes devices used outside of the plates/screws.Patient #16 55-year-old female was implanted with a va lcp forefoot/midfoot plates (02.211.265) with 6 screws.Two additional adjunctive fixation biomaterials was used for fusion augmentation / bone loss.Post op complication was reported for worsening pain & swelling in foot w/ progressive collapse of midfoot consistent w/ nonunion and failure arthrodesis of the talonavicular joint.The complication is noted to be related to the procedure or implants.Treatment: 1.First stage revision talonavicular arthrodesis left foot; removal of deep hardware high talus navicular first metatarsal and middle cuneiform and second metatarsal; debridement nonunion talonavicular cuneiform arthrodesis; placement of antibiotic spacer 2.Second stage complex revision medial column arthrodesis left foot; left foot total navicular replacement; arthrodesis talonavicular arthrodesis navicular cuneiform; removal of cement spacer.This report is for a 2.4/2.7mm va-lcp t-fusion pl 3 hole head/extra long.This is report 1 of 7 for (b)(4).
|
| |
|
Search Alerts/Recalls
|
|
|