EXACTECH, INC. NV GXL LINR, NTRL, 36MM ID, GROUP 4 CUPS; PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/CERAMIC/POLYMER, CEMENTED OR NON-POROUS
|
Back to Search Results |
|
| Catalog Number |
130-36-54 |
| Medical Device Problem Codes |
Naturally Worn (2988); Insufficient Device Problem Information (3190)
|
| Health Effect - Clinical Codes |
Osteolysis (2377); Insufficient Information (4580)
|
| Date of Event |
11/02/2023
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
H10.D10.Concomitants: 4148874, 164-01-14 - element-stem, collarless w/ha, std offset, sz 14.4653649, 170-36-00 - biolox delta femoral head 36mm od, +0mm.4617767, 170-36-03 - biolox delta femoral head 36mm od, +3.5mm.4488386, 186-01-60 - integrip cc, cluster 60mm, g4.Presumed left hip -4415175, 130-36-54 - nv gxl linr, ntrl, 36mm id, group 4 cups, serial number (b)(6) is confirmed to have been packaged in a vacuum bag that does not contain evoh.H3.Investigation results: the nv gxl linr, ntrl, 36mm id, group 4 cups device with serial number (b)(6) is confirmed to have been packaged in a vacuum bag that does not contain evoh.The cause of the patient's condition and the reason for the planned revision are not reported.There is insufficient information to determine the relationship of the devices to the patient's condition at this time.When more information is received it will be evaluated and additional actions taken as appropriate.These devices are used for treatment not diagnosis.H6.Health effect - impact code is for pending surgical revision.There is no other information available.
|
| |
|
Event or Problem Description
|
|
It was reported via legal documentation that a patient had a total right hip arthroplasty on (b)(6) 2016, with a planned revision, as of (b)(6) 2024 the revision date and surgical information have not been received.Scheduled date for revision was reported to be (b)(6) 2023.There is no other information provided/available.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional and/or corrected information.The following sections were updated: d7a.The following sections were corrected: b1 b2 g2 h6.The most likely cause for the reported revision due to prosthesis wear and osteolysis is a combination of the risk factors such as use error, implant positioning, implant size selection, and patient factors (fitness for surgery, biomechanics, activity level and local tissue oxidation potential).However, this cannot be confirmed as the devices were not returned for evaluation, and images and radiographs were not provided.If any further information is obtained that would change or alter any information provided, a supplemental report will be filed accordingly.
|
| |
|