| Catalog Number |
02.211.201 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Unspecified Infection (1930); Pain (1994)
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
In collaboration with depuy synthes, dr., together with (b)(6) clinic foundation database designers, program managers, research assistants, and biostatisticians, has developed a report that summarizes safety and effectiveness data on 100 patients who underwent foot surgery at (b)(6) between 2008 and 2023 utilizing depuy synthes (dps) foot plates.Some patients were noted to have adjunctive depuy synthes devices used outside of the plates/screws.Patient #25 70-year-old male was implanted with a va lcp forefoot/midfoot plates (02.211.201) with 4 screws.One additional adjunctive fixation screw was used for fixation.Post op complication was reported 1.Persistent pain; 2.Osteomyelitis of calcaneus (post-1st revision surgery) the complication is noted to be related to the procedure or implants.There is no device failure noted.Treatment: 1.Removal hardware foot (right), 1.2 screws from talocalcaneal arthrodesis 2.Second incision.4 screws and 1 plate, in addition, one 6.5 mm screw from a third incision from the talonavicular arthrodesis 3.Application of hydrocet bone graft ; 2.Debridement of right calcaneus osteomyelitis, which included debridement of bone, skin, subcutaneous and tendinous tissue ultrasound debridement and irrigation of wound with antibiotics placement of osteoset , vancomycin beads primary closure with the addition privina wound vac.This report is for a 2.4/2.7mm va-locking x-plate extra small.This is report 1 of 5 for (b)(4).
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.H10 additional narrative: d2: additional procode: hwc.D9: complainant part is not expected to be returned for manufacturer review/investigation.E3: initial reporter is a synthes employee.H3, h4, h6: without a lot number the device history records review could not be completed.Product was not returned.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Search Alerts/Recalls
|
|
|