• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ARTHREX, INC. NANO SWIVELOCK, 2.5 X 7MM W/ FORK EYELET; BONE FIXATION SCREW/PLATE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARTHREX, INC. NANO SWIVELOCK, 2.5 X 7MM W/ FORK EYELET; BONE FIXATION SCREW/PLATE Back to Search Results
Model Number NANO SWIVELOCK, 2.5 X 7MM W/ FORK EYELET
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code Insufficient Information (4580)
Date of Event 03/11/2024
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The contribution of the device to the reported event could not be determined as the device was not returned for evaluation.The root cause of the event could not be determined from the information available and without device evaluation.If the device becomes available for evaluation, a follow-up report will be submitted.
 
Event or Problem Description
On 21st march 2024, it was reported by a sales rep.Via email that for an ar-8998t, nano swivelock® suture anchor with fork eyelet, the screwdriver part of the inserter broke off on insertion of anchor.This was detected during an unspecified procedure on (b)(6) 2024.25th march 2024 - the sales rep.Replied that this was detected during use in a ucl procedure.The procedure was completed successfully as the other driver from the other swivelock was used but also became damaged.4th april 2024 - the sales rep.Replied that the other driver was also damaged as it was bent.However, the procedure was completed successfully as they made do with the bent driver.The surgeon was not happy and wanted a singly wrapped spare string driver.
 
Additional Manufacturer Narrative
The complaint allegation is confirmed based on the photo provided by the customer.Visual evaluation revealed the tip of the driver is broken off.Arthrex was able to conclude a most likely cause.The most likely cause for the reported failure can be attributed to over-torquing the screw when inserting into the plate and/or hard bone.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NANO SWIVELOCK, 2.5 X 7MM W/ FORK EYELET
Common Device Name
BONE FIXATION SCREW/PLATE
Manufacturer (Section D)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer (Section G)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer Contact
jared engle
8009337001
MDR Report Key19098383
Report Number1220246-2024-02009
Device Sequence Number7344467
Product Code HWC
UDI-Device Identifier10888867301822
UDI-Public10888867301822
Combination Product (Y/N)N
Initial Reporter CountryAS
PMA/510(K) Number
K191651
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Distributor
Initial Reporter Occupation Administrator/Supervisor
Type of Report Initial,Followup
Report Date (Section B) 08/16/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberNANO SWIVELOCK, 2.5 X 7MM W/ FORK EYELET
Device Catalogue NumberAR-8998T
Device Lot Number15043416
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/21/2024
Supplement Date Received by Manufacturer07/23/2024
Initial Report FDA Received Date04/12/2024
Supplement Report FDA Received Date08/21/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured01/11/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-