• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BAYLIS MEDICAL COMPANY INC. VERSACROSS LARGE ACCESS SOLUTION; DILATOR, VESSEL, FOR PERCUTANEOUS CATHETERIZATION

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BAYLIS MEDICAL COMPANY INC. VERSACROSS LARGE ACCESS SOLUTION; DILATOR, VESSEL, FOR PERCUTANEOUS CATHETERIZATION Back to Search Results
Lot Number VLFC230423
Medical Device Problem Codes Device-Device Incompatibility (2919); Difficult to Advance (2920); Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/06/2023
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The device has been received for analysis, and upon completion of the failure analysis of the complaint device, the failure could not be reproduced, since a 0.035" versacross rf wire and mechanical j-wire were able to be backloaded and frontloaded into the device with no resistance during benchtop testing on the returned device.No evidence of dilator kinking or tip ovality was noted.However, a scuffing of the dilator curve, and also a minor tip defect outside of lumen (extra material) were noted during visual inspection.Thus, this initial mdr is being filed.If there is any further relevant information from that review, a supplemental medwatch will be filed.
 
Event or Problem Description
It was reported that during the insertion of the mitra clip procedure to treat mitral valve, a versacross large access solution kit was selected for use.It has been mentioned that versacross dilator was not able to be front load with the versacross rf wire.The troubleshooting steps included back loading the dilator.The procedure was completed successfully by using another versacross kit.No patient complications have been reported.The product was expected to be returned.However, analysis of the device returned revealed a scuffing of the dilator curve, and a minor tip defect outside of lumen, extra material noted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VERSACROSS LARGE ACCESS SOLUTION
Common Device Name
DILATOR, VESSEL, FOR PERCUTANEOUS CATHETERIZATION
Manufacturer (Section D)
BAYLIS MEDICAL COMPANY INC.
5959 trans-canada highway
montreal H4T 1 A1
CA  H4T 1A1
Manufacturer (Section G)
BAYLIS MEDICAL COMPANY INC.
5825 explorer drive
mississauga, on L4W 5 P6
CA   L4W 5P6
Manufacturer Contact
timothy degroot
4100 hamline avenue north
dc a330
saint paul, MN 55112
6515826168
MDR Report Key19106884
Report Number2124215-2024-22626
Device Sequence Number20734705
Product Code DRE
UDI-Device Identifier00685447012535
UDI-Public00685447012535
Combination Product (Y/N)N
Initial Reporter CountryCA
PMA/510(K) Number
K201288
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 04/15/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date02/28/2026
Device Lot NumberVLFC230423
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/16/2024
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 04/12/2024
Initial Report FDA Received Date04/15/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured04/27/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Unknown
Patient Sequence Number1
Patient SexUnknown
-
-