| Model Number |
M00566460 |
| Medical Device Problem Codes |
Break (1069); Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
03/01/2024
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported to boston scientific corporation that an endovive safety peg kit pull method was attempted to be used during an esophagogastroduodenoscopy (egd) procedure.The procedure date was unknown.During the procedure, when the user pulled the g-tube through the abdomen, the pull wire broke.The procedure was able to be completed successfully with the original peg kit pull method.There were no patient complications reported as a result of this event.
|
| |
|
Additional Manufacturer Narrative
|
|
Block b3: approximated based on the date the manufacturer became aware of the event.Block h6: imdrf device code a0401 captures the reportable event of pull wire broken.
|
| |
|
Event or Problem Description
|
|
It was reported to boston scientific corporation that an endovive safety peg kit pull method was attempted to be used during an esophagogastroduodenoscopy (egd) procedure.The procedure date was unknown.During the procedure, when the user pulled the g-tube through the abdomen, the pull wire broke.The procedure was able to be completed successfully with the original peg kit pull method.There were no patient complications reported as a result of this event.
|
| |
|
Additional Manufacturer Narrative
|
|
Block b3: approximated based on the date the manufacturer became aware of the event.Block h6: imdrf device code a0401 captures the reportable event of pull wire broken.Block h11: the returned endovive safety peg kit pull method was analyzed.One pull method peg tube with the retrieval loop and one pull wire was returned for analysis.Visual inspection of the end of the loop confirmed the presence of damage in the form of a break.Visual inspection of the pull wire noted the presence of a tight knot/loop which was most likely the portion of the retrieval loop that broke.The pull wire was returned detached.No other problems with the device were noted.With all available information, boston scientific concludes the reported event of pull wire break was confirmed during the product investigation.Based on the condition of the returned device, it is possible that excessive force/tension applied during use caused the retrieval loop and pull wire to strain and subsequently break/detach.Therefore, the most probable root cause is adverse event related to procedure.
|
| |
|