• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ZIMMER BIOMET, INC. 25MM VERSA-DIAL TAPER ADAPTOR; COMPREHENSIVE SHOULDER SYSTEM MINI TAPER ADAPTOR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ZIMMER BIOMET, INC. 25MM VERSA-DIAL TAPER ADAPTOR; COMPREHENSIVE SHOULDER SYSTEM MINI TAPER ADAPTOR Back to Search Results
Catalog Number 118000
Medical Device Problem Code Detachment of Device or Device Component (2907)
Health Effect - Clinical Code Joint Dislocation (2374)
Date of Event 03/06/2024
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that the patient underwent an initial left shoulder arthroplasty approximately six (6) weeks ago.Subsequently, the patient was seen by their surgeon three (3) weeks later and it was discovered that the implants had disassociated.The patient underwent a revision surgery approximately three weeks ago.
 
Additional Manufacturer Narrative
(b)(4).D10: medical products: item#: 110027734, compr vrs glen pps min tpr adr; lot#: 66573916.Item#: 110030776, cr 40mm glenosphere std cocr; lot#: 65398246.H3: product has been received by zimmer biomet and the investigation is in process.Once the investigation has been completed, a follow-up mdr will be submitted.
 
Additional Manufacturer Narrative
(b)(4).This follow-up report is being submitted to relay additional and corrected information.The following sections were corrected: a3; d4.Visual examination of the returned product/provided pictures identified one 25mm versa-dial taper adaptor item# 118000 lot#j7614800 was returned and evaluated.Upon visual inspection the taper adapter there are galling to post.Review of the device history record(s) identified no deviations or anomalies during manufacturing.Radiographs were provided and reviewed by a health care professional.Review of the available records identified the following: there is a reverse-type left shoulder arthroplasty.The glenosphere is disassociated and displaced from the glenoid baseplate and the proximal humerus is anterosuperiorly subluxed/dislocated in relation to the glenoid.Operative change is noted at the acromioclavicular joint and there is regional heterotopic ossification.There is no fracture or evidence of implant loosening.Bone quality is osteopenic.A definitive root cause cannot be determined.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Event or Problem Description
No further event information available at the time of this report.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
25MM VERSA-DIAL TAPER ADAPTOR
Common Device Name
COMPREHENSIVE SHOULDER SYSTEM MINI TAPER ADAPTOR
Manufacturer (Section D)
ZIMMER BIOMET, INC.
56 e. bell drive
p.o. box 587
warsaw IN 46581
Manufacturer (Section G)
ZIMMER BIOMET, INC.
56 e. bell drive
p.o. box 587
warsaw IN 46581
Manufacturer Contact
jennifer rapsavage
56 e. bell dr.
warsaw, IN 46582
5745260384
MDR Report Key19132990
Report Number0001825034-2024-01047
Device Sequence Number17300980
Product Code PHX
UDI-Device Identifier00880304531048
UDI-Public(01)00880304531048(17)331005(10)J7614800
Combination Product (Y/N)N
Initial Reporter StateCA
Initial Reporter CountryUS
PMA/510(K) Number
K193373
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2024
Device Explanted Year2024
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 08/20/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number118000
Device Lot NumberJ7614800
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/09/2024
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/22/2024
Supplement Date Received by Manufacturer08/16/2024
Initial Report FDA Received Date04/18/2024
Supplement Report FDA Received Date08/22/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured10/05/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention; Other;
Patient SexMale
-
-