| Model Number |
GIF-N180 |
| Medical Device Problem Code |
Microbial Contamination of Device (2303)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
02/21/2024
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported that during reprocessing, the gastrointestinal videoscope tested positive for 7 colony forming units (cfus)/100ml of aerobic microorganisms.A subsequent test was performed and tested positive for 8 cfu's/100ml of aerobic microorganisms.All channels were sampled.The user did not report any contamination or any other serious deterioration in state of health of any person, to which the scope could have been a contributory cause.
|
| |
|
Additional Manufacturer Narrative
|
|
The device evaluation is ongoing.Prior to the device evaluation, the device was sent out for additional microbiological testing.The microbiological analysis results are pending.Once the investigation has been completed, a supplemental report will be submitted with device evaluation results.
|
| |
|
Additional Manufacturer Narrative
|
|
This report is being supplemented to provide additional information based on the legal manufacture's (lm) review of the customer completed cleaning disinfection and sterilization (cds) checklist, results of third-party testing, the device evaluation and the lms final investigation.The lm reviewed the customer provided the cds processes where no obvious deviations from instructions for use (ifu) were identified.Olympus provided the following result of the culture test, performed at the third-party labs: sampling date: on (b)(6) 2024 sampling from: all channels cfu: 2 cfu bacterial identification: bacillaceae the device was evaluated where no abnormalities were found that could have led to the positive culture.A review of the device history record found no deviations that could have caused or contributed to the reported issue.Based on the results of the investigation, the relevance between the device and the detection of bacteria could not be established and a root cause could not be determined.The following is included in the device ifu: ¿an insufficiently reprocessed endoscope and/or accessory may pose an infection control risk to the patients and/or operators who touch them.¿ olympus will continue to monitor field performance for this device.
|
| |
|
Search Alerts/Recalls
|