EXACTECH, INC. EQUINOXE REVERSE 42MM HUMERAL CONST LINER +2.5; PROSTHESIS, SHOULDER, NON-CONSTRAINED, METAL/POLYMER CEMENTED
|
Back to Search Results |
|
| Catalog Number |
320-42-13 |
| Medical Device Problem Code |
Naturally Worn (2988)
|
| Health Effect - Clinical Codes |
Failure of Implant (1924); Pain (1994)
|
| Date of Event |
03/21/2024
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
7033170 - 300-30-11 - equinoxe preserve stem 11mm a149071 - 320-06-42 - glenosphere 42mm a135617 - 320-10-00 - equinoxe reverse tray adapter plate tray +0 a163013 - 320-15-05 - eq rev locking screw 6144875 - 320-15-07 - sup/post aug plate, l rs glenoid baseplate a124848 320-20-00 - eq reverse torque defining screw kit a166821 - 320-20-26 - eq rev compress screw lck cap kit, 4.5 x 26mm a039019 - 320-20-30 - eq rev compress screw lck cap kit, 4.5 x 30mm a141012 - 320-20-34 - eq rev compress screw lck cap kit, 4.5 x 34mm 6029281 - 320-20-42 - eq rev compress screw lck cap kit, 4.5 x 42mm 6097913 - 320-20-46 - eq rev compress screw lck cap kit, 4.5 x 46mm s336228 - 320-42-00 - 145-deg pe 42mm hum liner +0 (b)(6) - 320-42-13 - 145-deg pe 42mm const hum liner +2.5.
|
| |
|
Event or Problem Description
|
|
It was reported that a 81 yo male patient, initial left shoulder implanted on (b)(6) 2022, underwent a revision procedure on (b)(6) 2024, approximately 1 year 5 months post the initial procedure.The patient presented with complaints of pain.Bad poly indicated.The poly was replaced.There were no device breakages or surgical delays during the procedure.No x-rays were provided.The patient was last known to be in stable condition following the event.The explanted device is not available for return.Chain of command, due to the recall the hospital will not release it.A device image was provided.No further information.No other patient information/medical history reported.
|
| |
|
Event or Problem Description
|
|
It was reported that a 81 yo male patient, initial left shoulder implanted and then underwent a revision procedure, approximately 1 year 5 months post the initial procedure.The patient presented with complaints of pain.Bad poly indicated.The poly was replaced.There were no device breakages or surgical delays during the procedure.No x-rays were provided.The patient was last known to be in stable condition following the event.The explanted device is not available for return.Chain of command, due to the recall the hospital will not release it.A device image was provided.No further information.No other patient information/medical history reported.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional and/or corrected information.The following sections were updated/corrected: d6a, h6.Mdr section codes updated/corrected: b, c, d, e.The revision reported was likely the result of prosthesis wear on the rim of the humeral liner, which may have been due to scapular notching.Potential contributions of user and patient-related considerations to the event could not be assessed as the devices were not available for evaluation and radiographs and relevant clinical information were not provided.Should additional relevant information be obtained, a follow-up mdr will be submitted accordingly.
|
| |
|