| Catalog Number |
03.045.001 |
| Medical Device Problem Code |
Device-Device Incompatibility (2919)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported that on an unknown date, the screwdriver was jammed within the cannulation.It did not allow the retention pin to be inserted normally and would not allow the use of the self-retaining feature.The pin was getting blocked before falling into the screwdriver and the cannulation feels too narrow for the pin.Surgeon tied to clear the pin with a brush but nothing was working.Only one out of the 4 seemed to be faulty.There was no patient involvement.The issue was discovered before it could use in a case.This report is for one (1) screwdriver xl25 this is report 1 of 1 for complaint (b)(4).
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.D9: complainant part is expected to be returned for manufacturer review/investigation, but has yet to be received.E3: reporter is a j&j employee.H3, h4, h6: without a lot number the device history records review could not be completed.The investigation could not be completed; no conclusion could be drawn, as no product was received.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.H3, h4, h6: part number: 03.045.001.Lot number: 5547p47.Manufacturing site: haegendorf.Release to warehouse date: 5th june 2023.A manufacturing record evaluation was performed for the finished device lot number, and no non-conformances were identified.The video was returned to depuy synthes for evaluation.The depuy synthes team conducted a visual inspection of the returned photo/video.Visual analysis of the video revealed that the mating retention pin device was unable to assemble /disassemble from the screw driver/cannulated/xl25.In addition, with the evidence provided is not possible determine a potential cause or any other issue.However, if internal damage on the threads is present, the assembling issues are more likely due to this condition.As the device was not returned, an as-received condition could not be assessed, and a dimensional inspection and document/specification review were not completed.As part of depuy synthes quality process, all devices are manufactured, inspected, and released to approved specifications.The overall complaint was confirmed.There is no indication that a design or manufacturing issue has caused the complaint condition.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post-market safety surveillance activities.Correction: g1: manufacturing site name and address.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.H3, h6: a product investigation was conducted.The product was returned to depuy synthes for evaluation.The depuy synthes team conducted a visual inspection of the returned device.Visual analysis of the returned sample revealed that screwdriver/cannulated/xl25 was observed with signs of usage.No other issues were identified.A dimensional inspection for the screw driver/cannulated/xl25 was not performed due to post manufacturing damage.A functional test was performed using a mating device sample (part number: 03.045.002 retention pin for screwdriver xl25) and confirm the inability to connect correctly both devices.The complaint condition was able to be replicated.The observed condition of the device was consistent with a random component failure that may have been caused by exposure to unintended forces causing an internal damaged to threads which prevents the correct connection between the devices.As part of depuy synthes quality process, all devices are manufactured, inspected, and released to approved specifications.The overall complaint was confirmed as the observed condition of the screw driver/cannulated/xl25 would contribute to the complained device issue.There is no indication that a design or manufacturing issue has caused the complaint condition.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post-market safety surveillance activities.Part number: 03.045.001-us, lot number: 5442p24, manufacturing site: haegendorf, release to warehouse date: 02-may-2023.A manufacturing record evaluation was performed for the finished device batch number, and no non-conformances related to the malfunction were identified.A non product non-conformance jbl-nr-was opened to correct the document references in the routers and in the dhr.This nc is affecting only the document reference with no changes to content of the documents and the products are not impacted.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|