| Model Number |
LOGIC TIBIA IMPLANT PSC INSERT, SZ 3.5, 9MM |
| Medical Device Problem Codes |
Naturally Worn (2988); Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Granuloma (1876); Synovitis (2094); Joint Laxity (4526); Implant Pain (4561)
|
| Date of Event |
02/27/2024
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
As reported, approximately three years post initial left tka, the male patient was suffering from laxity and pain.Patient had a revision surgery an early granuloma on pe synovectomy was performed, liner pe changed.There was no breakage of device or surgical delay/prolongation.Sales rep was unable to obtain photos/x-rays.The device is not available for evaluation.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information, including the product investigation, will be submitted within 30 days of receipt.
|
| |
|
Additional Manufacturer Narrative
|
|
H10.Related- mfr #1038671-2024-02590 report 1 of 2.H11.Additional manufacturer narrative- report 1 of 2.Additional information added.D10.Concomitants: sn (b)(6) - cat #02-010-02-0235.Sn (b)(6) - cat #02-012-45-3535.Sn (b)(6) - cat #200-02-35.Sn (b)(6) - cat #204-34-04.Sn (b)(6) - cat #204-70-00.H3.Investigation results- photo: posterior tibial spine wear is likely to occur when the post is chronically subjected to higher-than-normal shear forces and/or rapid, rather than gradual engagement of the femoral cam with the tibial insert spine during knee flexion.The damage on the tibial spine suggests that there may have been some level of knee instability.Instability occurs when the soft-tissue structures around the knee are unable to provide the stability necessary for adequate function during standing or walking.Instability may be the result of increased soft-tissue laxity (looseness), inadequate flexion of the implants, or improper positioning or alignment of the prosthesis.Pain and/or a sense of ¿giving away¿ of the knee may alter knee function and require revision surgery.The frequency of occurrence ranking is "very low".The tibial insert was packaged for approximately 5.42 years before being implanted.Risk documents were reviewed, risks are captured.The revision reported was likely the result of tibial insert wear and instability.Additionally, a contributing factor to the reported wear of the tibial insert may have been the result of being packaged in a non-conforming vacuum bag for more than five years.However, the extent and likely cause of the prosthesis wear and instability could not be determined as the devices were not returned for evaluation, and radiographs and images of the patella were not provided.These devices are used for treatment not diagnosis.There is no additional information available.
|
| |
|
Event or Problem Description
|
|
Revision operative report - painful synovitis and laxitis of the left knee.Removal of total left knee prosthesis by synovectomy and insert change.Synovectomy.The insert shows signs of microscopic wear.Moderate balanced patellar wear.The "ball joint is not loose".The ¿anchoring¿ of the tibial and femoral components was performed and noted to be ¿perfect¿.There were no difficulties or unforeseen events noted.Patient to begin rehabilitation post operatively.Patient outcome was not provided.There is no additional information available.
|
| |
|