Catalog Number 26374
Medical Device Problem Code Failure to Osseointegrate (1863)
Health Effect - Clinical Codes Fistula (1862); Failure of Implant (1924); Unspecified Infection (1930); Inflammation (1932); Pocket Erosion (2013); Osteolysis (2377)
Date of Event 04/15/2024
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Therefore, because a serious injury resulted, this event is reportable per 21 cfr part 803.The device was not evaluated because the issue is a known inherent risk of the device.We will continue to track and monitor the trend.
 
Event or Problem Description
It was reported that a patient experienced a dental implant loss.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ASTRATECH IMPL EV 4.2PS 13MMOS
Common Device Name
IMPLANT, ENDOSSEOUS, ROOT-FORM
Manufacturer (Section D)
DENTSPLY IMPLANTS MANUFACTURING GMBH
rodenbacher chaussee 4
hanau hessen 63457
GM  63457
Manufacturer (Section G)
DENTSPLY IMPLANTS MANUFACTURING GMBH
rodenbacher chaussee 4
hanau hessen 63457
GM   63457
Manufacturer Contact
hannah seevaratnam
221 west philadelphia st.
york, PA 17401
7178457511
MDR Report Key19171572
Report Number3013111692-2024-12154
Device Sequence Number12626598
Product Code DZE
UDI-Device Identifier07392532214615
UDI-Public07392532214615
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K130999
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2024
Device Explanted Year2024
Reporter Type Manufacturer
Report Source Foreign,Health Professional
Initial Reporter Occupation Dentist
Type of Report Initial
Report Date (Section B) 04/24/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Catalogue Number26374
Device Lot Number503058
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Distributor Facility Aware Date04/19/2024
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 04/19/2024
Initial Report FDA Received Date04/24/2024
Was Device Evaluated by Manufacturer? (Y/N) No
Usage of Device A
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-