• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ZIMMER BIOMET, INC. -6MM EXTENDED NEUTRAL HUMERAL TRAY; IDENTITY SHOULDER SYSTEM -6MM EXTENDED NEUTRAL HUMERAL TRAY

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ZIMMER BIOMET, INC. -6MM EXTENDED NEUTRAL HUMERAL TRAY; IDENTITY SHOULDER SYSTEM -6MM EXTENDED NEUTRAL HUMERAL TRAY Back to Search Results
Catalog Number SAHTNEM6
Medical Device Problem Codes Device Dislodged or Dislocated (2923); Noise, Audible (3273)
Health Effect - Clinical Codes Pain (1994); Joint Dislocation (2374)
Date of Event 03/27/2024
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
(b)(4).D10: medical products: item#: 00436003600, glenosphere centric 36 mm diameter +0 mm lateral offset, lot#: 66323916.Item#: 110031419, +3mm thickness 36mm diameter bearing, lot#: 65381485.H3: product has been received by zimmer biomet and the investigation is in process.Once the investigation has been completed, a follow-up mdr will be submitted.
 
Event or Problem Description
It was reported that the patient underwent an initial shoulder reverse shoulder arthroplasty approximately two (2) and a half months ago.The patient was doing great two (2) months post op having no pain and full elevation when the patient reached for a coat in a car and felt a sudden pain and clicking sensation in their shoulder.Subsequently, the surgeon scheduled the patient for a revision of the reverse identity stem.During the revision, it was discovered by the surgeon that the implant was no longer engaged.The implant was free floating in the shoulder joint.
 
Event or Problem Description
No further event information available at the time of this report.
 
Additional Manufacturer Narrative
(b)(4).This follow-up report is being submitted to relay additional information.Visual examination of the returned product/provided pictures identified an identity -6mm extended neutral humeral tray.Was returned for evaluation.As returned, damage is seen in the inner tray, rim feature, and backside.The taper show wear & tear.Review of the device history records identified no deviations or anomalies during manufacturing.Medical records/radiographs were provided and reviewed by a health care professional.Review of the available records identified the following: single ap view of the right shoulder dated (b)(6) 2024 demonstrates narrowing of the glenohumeral joint with metal-on-metal appearance suggesting polyethylene spacer dislocation, with radiolucent spacer possibly within the subacromial sub deltoid space.A definitive root cause cannot be determined.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
-6MM EXTENDED NEUTRAL HUMERAL TRAY
Common Device Name
IDENTITY SHOULDER SYSTEM -6MM EXTENDED NEUTRAL HUMERAL TRAY
Manufacturer (Section D)
ZIMMER BIOMET, INC.
1800 w. center st.
warsaw IN 46580
Manufacturer (Section G)
ZIMMER BIOMET, INC.
1800 w. center st.
warsaw IN 46580
Manufacturer Contact
jennifer rapsavage
56 e. bell dr.
warsaw, IN 46582
5745260384
MDR Report Key19172327
Report Number0001822565-2024-01387
Device Sequence Number12595320
Product Code MBF
UDI-Device Identifier00889024627406
UDI-Public(01)00889024627406(17)330814(10)66046381
Combination Product (Y/N)N
Initial Reporter StateIL
Initial Reporter CountryUS
PMA/510(K) Number
K213856
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2024
Device Explanted Year2024
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Distributor
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 05/23/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue NumberSAHTNEM6
Device Lot Number66046381
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/09/2024
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/29/2024
Supplement Date Received by Manufacturer05/23/2024
Initial Report FDA Received Date04/24/2024
Supplement Report FDA Received Date05/23/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured08/17/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
SEE H11 NARRATIVE.
Outcome Attributed to Adverse Event Hospitalization; Required Intervention;
Patient Age69 YR
Patient SexUnknown
-
-