MENTOR TEXAS MENTOR MEMORYGEL XTRA BREAST IMPLANT; PROSTHESIS, BREAST, NONINFLATABLE, INTERNAL, SILICONE GEL-FILLED
|
Back to Search Results |
|
| Catalog Number |
SMPX215 |
| Medical Device Problem Codes |
Adverse Event Without Identified Device or Use Problem (2993); Migration (4003)
|
| Health Effect - Clinical Codes |
Capsular Contracture (1761); Deformity/ Disfigurement (2360)
|
| Date of Event |
01/02/2024
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
At the time of this report, mentor has received no information regarding explantation or an expected explantation date. it is unknown at this time if the device will be made available for return. as a result, no product failure analysis can be conducted, and no determination of possible contributing factors can be made. as such, the investigation will be closed. if the complaint device is received in the future, the investigation will be reopened and conducted as appropriate.A manufacturing record evaluation (mre) was performed, and no anomalies were found related to this complaint.In addition, the mre verifies that the device was manufactured in accordance with documented specification and procedures.Mentor is submitting this report pursuant to the provisions of 21 cfr, part 803. this report may be based on information which mentor has not been able to investigate or verify prior to the required reporting date. this report does not reflect a conclusion by fda, mentor, or its employees that the report constitutes an admission that the device, mentor, or its employees caused or contributed to the potential event described in this report. if certain information is unknown, not available or does not apply, the section/field of the form is left blank.Reason for device explant and/or reoperation: the patient has not undergone explantation or reoperation at this time.Manufacturer¿s reference number: (b)(4).
|
| |
|
Event or Problem Description
|
|
It was reported that a patient underwent a primary breast augmentation surgery with implantation of a 215cc mentor memorygel xtra breast implant prosthesis.Post-operatively, the patient experienced a tight right breast.During a physical exam with a medical professional, she was noted to have a mildly contracted and painful right breast and a hypermobility of the left breast implant with fallout inferiorly and laterally.She was diagnosed with baker grade iv capsular contracture of the right breast.During a secondary follow-up visit, the patient's left capsule had tightened up which was noted to no longer need any revisional work.As a result, the patient is scheduled for unilateral right-sided removal and replacement on (b)(6) 2024.This report is for the left breast prosthesis.Refer to manufacturing report number 1645337-2024-04922 for the contralateral event.
|
| |
|
Additional Manufacturer Narrative
|
|
On july 09, 2024, mentor was notified that the patient decided to remove and replace both implants on (b)(6) 2024.Since the device has not been returned for analysis, no product failure analysis can be conducted, and no determination of possible contributing factors can be made. as such, the investigation will be closed. if the complaint device is received in the future, the investigation will be reopened and conducted as appropriate.Reason for device explant and/or reoperation: device migration date of explantation: august 06, 2024 manufacturer¿s reference number: (b)(4).
|
| |
|
Additional Manufacturer Narrative
|
|
On august 12, 2024, mentor received additional information that the patient was diagnosed with bilateral capsular contracture of the breasts.The baker grade rating for the left breast was not provided.As such, this file was updated with capsular contracture.This report is for the left breast prosthesis.Reason for device explant and/or reoperation: capsular contracture.On august 22, 2024, the mentor analysis lab received the suspect medical device for evaluation.On august 30, 2024, mentor became aware that the patient underwent bilateral removal and replacement with 240cc mentor memorygel xtra breast implants during the surgery.On september 04, 2024, mentor completed an evaluation on the returned device.Mentor conducted a visual inspection of the device.During visual evaluation no apparent damage or visual anomalies were observed on the breast implant.Mentor concluded that the capsular contracture in the patient´s breast was the result of the body´s individual physiological response to the implantation of a foreign object in soft tissue.Capsular contracture is a known complication associated with these devices and is referenced in our current product insert data sheet.The american society of plastic surgeons recommends and encourages member surgeons to always submit breast implants, capsule, and effusion to pathology for examination.Manufacturer¿s reference number: (b)(4).
|
| |
|