W. L. GORE & ASSOCIATES, INC. GORE® EXCLUDER® AAA ENDOPROSTHESIS; SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT
|
Back to Search Results |
|
| Catalog Number |
RLT311413 |
| Medical Device Problem Codes |
Positioning Problem (3009); Insufficient Device Problem Information (3190)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
04/09/2024
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
H.6.: type of investigation: code b21: results pending completion of investigation.H.6.:investigation findings: code c21: results pending completion of investigation.H.6.:investigation conclusions: code d16: conclusion not yet available.H.6.: medical device problem: code a26:results pending completion of investigation.W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
|
| |
|
Event or Problem Description
|
|
The following information was reported to gore: on (b)(6) 2024, a patient underwent endovascular treatment of a zone 9 abdominal aortic aneurysm.It was reported that while preparing a gore® excluder® aaa endoprosthesis rlt311413 for use, the device was loaded onto an amplatz 260cm wire.While advancing the wire, the physician reported that it was very difficult to advance the device.The physician pulled the device off the wire, and re-prepped the device wiping the wire down with heparinized saline.The wire was inserted without difficulty.However, the physician then noticed that the locking wire normally attached to the nose cone was detached and free floating.He was not comfortable advancing the device with an exposed wire into the aorta, and pulled the device off the amplatz.A second gore® excluder® aaa endoprosthesis rlt311413 was used to complete the procedure without further difficulty.The patient tolerated the procedure.The device will be returned for evaluation.
|
| |
|
Additional Manufacturer Narrative
|
|
Added g3/g4, h1/h2, h3 and h6.H.6.: type of investigation: code b21 updated to code b01 h.6.:investigation findings: code c21: updated to code c19 h.6.: investigation conclusions: code d16: updated to code d12 and d15 h.6.: medical device problem: code a26: updated to a1502 according to the gore® excluder® aaa endoprosthesis instructions for use (ifu), potential device or procedure-related adverse events that may occur and/or require intervention include, but are not limited to, endoleak and aneurysm enlargement and, or improper component placement, and component migration.H.3.: the device evaluation showed the following: visual examination of the device did not reveal any kinks.However, it was revealed that the lock pin was not engaged in the hole on the leading olive and there was a gap between the leading end of the endoprosthesis and the leading olive.Visual examination of the leading olive did not reveal any abnormalities.Engineering inserted a guidewire per the ifu and was able to do so with no observed resistance.The guidewire was advanced the length of the delivery catheter.Engineering was able to remove the guidewire with no observed resistance.Based on the findings from this evaluation, the physician¿s observation that ¿it was very difficult to advance" could not be confirmed.Based on the findings from this evaluation, the physician¿s observation that ¿the locking wire normally attached to the nose cone was detached and free floating¿ could be confirmed.The likely cause for the reported difficulty advancing the gore® excluder® aaa endoprosthesis over the guidewire could not be determined with the available information.The likely cause for the gore® excluder® aaa endoprosthesis lock pin becoming detached from the leading olive could not be determined with the available information.However, the lock pin may have been dislodged when the device was removed from the guidewire.
|
| |
|
Additional Manufacturer Narrative
|
|
Added g3/g4, h1/h2 h.6.: investigation conclusions: code d12 removed.
|
| |
|