ZIMMER BIOMET, INC. COMPREHENSIVE VRS MINI TAPER ADAPTOR; SHOULDER PROSTHESIS, REVERSE CONFIGURATION
|
Back to Search Results |
|
| Catalog Number |
110031378 |
| Medical Device Problem Code |
Detachment of Device or Device Component (2907)
|
| Health Effect - Clinical Code |
Bruise/Contusion (1754)
|
| Date of Event |
02/15/2024
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported that a few days following an initial arthroscopy procedure, the patient experienced implant dissociation.The patient underwent additional surgery approximately one (1) week following the original procedure, and the surgeon discovered that the central screw wasn't fully tightened, causing the looseness.The screw was adjusted, and other concomitant devices were retained during the revision, with no other patient harm reported.Attempts have been made, and no further information has been provided.
|
| |
|
Additional Manufacturer Narrative
|
|
(b)(4).D10: concomitant medical products, part number (lot number): 115396 (unknown), 110027734 (66500759).Associated product information: 113633 (64964350), 180554 (unknown), 180554 (unknown), 180555 (unknown), 180555 (unknown), 180556 (unknown), 405800 (66394301), 110010066 (66500764), 110030777 (66072611), 110031400 (66394125), 110031429 (65434183).The customer has indicated that the product will not be returned to zimmer biomet for investigation as it remains implanted.The investigation is in process.Once the investigation has been completed, a follow-up mdr will be submitted.If any further information is found that would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
|
| |
|
Additional Manufacturer Narrative
|
|
Corrections to d6b and d9; this product was explanted during the revision and returned for evaluation.The reported event is confirmed as the returned taper adaptor shows scuffs consistent with disassociation between the taper adaptor and the baseplate.Visual examination of the returned product/provided pictures identified the devices returned showed wear with the bearing being worn and the taper adaptor having scuff marks.The glenosphere has light scratches on the od.Measured the overall height and outer diameter of the glenosphere and both were conforming.A review of the device history record(s) identified no deviations or anomalies during manufacturing.Medical records were not provided.As it is unknown when the screw became unseated, a definitive root cause cannot be determined.If any further information is found which would change or alter any conclusions or information, a supplemental report will be filed accordingly.Zimmer biomet will continue to monitor for trends.
|
| |
|
Event or Problem Description
|
|
No further event information is available at the time of this report.
|
| |
|