| Catalog Number |
08.501.001.01S |
| Medical Device Problem Code |
Mechanical Problem (1384)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
04/08/2024
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported that during a surgery on (b)(6) 2024, the zip fix would not tighten.Changed another two to continue the surgery, the same problem happened again.Another device was used to complete the surgery.There were no adverse consequences to the patient.No surgical delay.This report is for one sternal zipfix with needle sterile for (b)(4).
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.H10 additional narrative: h3, h4, h6 investigation summary the photo was returned to depuy synthes for evaluation.The depuy synthes team conducted a visual inspection of the returned photo.Visual analysis of the photo revealed that sternal zipfix with needle sterile was observed in used conditions.Functionality issues cannot be assessed through a photo investigation.As the device was not returned, an as-received condition could not be assessed, and a dimensional inspection and document/specification review were not completed.As part of depuy synthes quality process, all devices are manufactured, inspected, and released to approved specifications.The overall complaint was not confirmed for sternal zipfix with needle sterile.There is no indication that a design or manufacturing issue has caused the complaint condition.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post-market safety surveillance activities.Device history a manufacturing record evaluation was performed for the finished device product code : 08.501.001.01s.Lot number# 703p924.It was electronically reviewed and no nonconformances / manufacturing irregularities were identified during the manufacturing process.The product was released on: 02-jun-2022.Manufacturing site:jabil bettlach.Expiry date:01-may-2027.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.H3, h6: a product investigation was conducted.The product was returned to depuy synthes for evaluation.The depuy synthes team conducted a visual inspection of the returned device.Visual analysis of the returned sample revealed that sternal zipfix with needle sterile was inserted through the incorrect side of the locking head.A review of the surgical technique guide se_839363 rev.Ab found that it clearly shows the end of the implant being inserted into the wide side of the locking head.This can be related to the will not tension allegation.Per sternal zipfix surgical technique guide se_839363 rev.Ab.Precautions: do not damage the implant teeth and locking head by manipulating with instruments.To avoid damage to the locking head: stainless steel needles must be removed before closing the zipfix implant.Prior to insertion of the cut end, ensure the zipfix implant is properly oriented such that the toothed surface contacts the sternum.Align the cut end with the locking head during insertion.Do not insert at an angle.Avoid excessive force when tightening implant.Do not use forceps to tighten implant.Damage resulting from excessive force or forceps may cause implant failure.Ensure that the implant body is not twisted while passing the cut end through the locking head.Zipfix implant should only be inserted once into the locking head.A dimensional inspection for the sternal zipfix with needle sterile was not performed due to post manufacturing damage.The observed condition of the device was consistent with a random component failure that may have been caused by exposure to unintended forces.As part of depuy synthes quality process, all devices are manufactured, inspected, and released to approved specifications.The overall complaint was confirmed as the observed condition of the sternal zipfix with needle sterile would contribute to the complained device issue.There is no indication that a design or manufacturing issue has caused the complaint condition.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post-market safety surveillance activities.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Search Alerts/Recalls
|
|
|