• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ARTHREX, INC. IMPL SYS,CMC MINI T-ROPE,1.1 MM; WASHER, BOLT, NUT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARTHREX, INC. IMPL SYS,CMC MINI T-ROPE,1.1 MM; WASHER, BOLT, NUT Back to Search Results
Model Number IMPL SYS,CMC MINI T-ROPE,1.1 MM
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code Insufficient Information (4580)
Date of Event 03/15/2024
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The contribution of the device to the reported event could not be determined as the device was not returned for evaluation.The root cause of the event could not be determined from the information available and without device evaluation.If the device becomes available for evaluation, a follow-up report will be submitted.
 
Event or Problem Description
On 4/8/2024, it was reported by a facility risk manager via an fda maude review email that the guidewire from an ar-8919ds cmc mini tightrope implant system broke during insertion.The surgeon attempted to retrieve the broken fragment with a hemostat; however, it bent.The fragment was successfully removed using a needle driver.An x-ray confirmed all the fragments were removed.This was discovered during a procedure on (b)(6) 2024.Additional information received on 4/15/2024: the medwatch notification reports that after the hemostat bent, a needle driver was used to retrieve the broken guidewire.However, when the needle driver was removed from the patient, it was noticed that the tip had broken off.A mini-c-arm x-ray was taken, which showed the tip inside the patient.A portable x-ray was performed to ensure that nothing was retained.The portable x-ray was deemed negative by the doctor.The case was completed, and no follow-up care was needed for the patient.Additional information received on 4/22/2024: the portable x-ray confirmed that the broken tip was never in the patient.Additional information requested.
 
Additional Manufacturer Narrative
Mw5153301.
 
Additional Manufacturer Narrative
Additional information: g3, h3, h6.Based on the information provided which may include the device (if available and returned), pictures, videos, event description, and any additional information from the field, arthrex was able to conclude a most likely cause.The most likely cause for the reported failure can be attributed to improper bone prep; misaligned insertion; prying/leveraging the device during insertion.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
IMPL SYS,CMC MINI T-ROPE,1.1 MM
Common Device Name
WASHER, BOLT, NUT
Manufacturer (Section D)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer (Section G)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer Contact
jared engle
8009337001
MDR Report Key19249585
Report Number1220246-2024-02829
Device Sequence Number20482658
Product Code HTN
UDI-Device Identifier00888867048966
UDI-Public00888867048966
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
K140328
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Other,Health Professional,User Facility
Initial Reporter Occupation Risk Manager
Type of Report Initial,Followup,Followup,Followup
Report Date (Section B) 05/19/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberIMPL SYS,CMC MINI T-ROPE,1.1 MM
Device Catalogue NumberAR-8919DS
Device Lot Number15077505
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 04/08/2024
Supplement Date Received by ManufacturerNot provided
Not provided
05/17/2025
Initial Report FDA Received Date05/06/2024
Supplement Report FDA Received Date07/18/2024
08/22/2024
05/19/2025
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured04/05/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-