• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: MEDOS INTERNATIONAL SàRL CH EXP DUAL-INNER SETSCREW; THORACOLUMBOSACRAL PEDICLE SCREW SYSTEM

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDOS INTERNATIONAL SàRL CH EXP DUAL-INNER SETSCREW; THORACOLUMBOSACRAL PEDICLE SCREW SYSTEM Back to Search Results
Catalog Number 179722000
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Unspecified Infection (1930)
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that the patient underwent a removal of hardware due to infection on (b)(6) 2024.Four screws, 3 lateral connectors, and 7 set screws were removed.This report involves one unk - rods: expedium for (b)(4).Additional impacted products related to this event are captured in (b)(4).Additionally, (b)(4) captures an instrument malfunction that occurred during the removal surgery.
 
Additional Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.H10 additional narrative: d9: complainant part is not expected to be returned for manufacturer review/investigation.E3: reporter is a j&j employee.H3, h4, h6: without a lot number the device history records review could not be completed.Product was not returned.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EXP DUAL-INNER SETSCREW
Common Device Name
THORACOLUMBOSACRAL PEDICLE SCREW SYSTEM
Manufacturer (Section D)
MEDOS INTERNATIONAL SàRL CH
chemin-blanc 38
le locle 02400
SZ  02400
Manufacturer (Section G)
MEDOS INT SPINE
chemin blanc 38
le locle
SZ  
Manufacturer Contact
kate karberg
325 paramount drive
raynham, MA 02767
3035526892
MDR Report Key19286033
Report Number1526439-2024-01433
Device Sequence Number20950720
Product Code NKB
UDI-Device Identifier10705034070070
UDI-Public(01)10705034070070
Combination Product (Y/N)N
Initial Reporter CountryAS
PMA/510(K) Number
K200245
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2011
Device Explanted Year2024
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number179722000
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 04/18/2024
Initial Report FDA Received Date05/10/2024
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Unknown
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
DI POLYAXL SCREW 8 X 65MM; DI POLYAXL SCREW 8 X 80MM; EXP DUAL-INNER SETSCREW; EXP DUAL-INNER SETSCREW; LATERAL CONNECTOR, 20MM; LATERAL CONNECTOR, 50MM; LATERAL CONNECTOR, 50MM; MIS SINGLE INNER SETSCW; MIS SINGLE INNER SETSCW; MIS SINGLE INNER SETSCW; MIS SINGLE INNER SETSCW; MIS SINGLE INNER SETSCW; MIS SINGLE INNER SETSCW; MIS SINGLE INNER SETSCW; SI POLYAXL SCREW 7 X 40MM; SI POLYAXL SCREW 7 X 40MM; UNK - RODS: EXPEDIUM
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-