| Model Number |
EVOLUTPRO-23-US |
| Medical Device Problem Codes |
Calcified (1077); Gradient Increase (1270); Inadequacy of Device Shape and/or Size (1583); Patient Device Interaction Problem (4001); Thickening of Material (4056); Device Stenosis (4066)
|
| Health Effect - Clinical Codes |
Aortic Valve Stenosis (1717); Thrombosis/Thrombus (4440)
|
| Date of Event |
05/06/2024
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Medtronic has requested additional information pertaining to this reportable event.If additional reportable information is received, a supplemental report will be submitted.Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
|
| |
|
Event or Problem Description
|
|
Medtronic received information that five years and nine months following the implant of this transcatheter bioprosthetic valve, valve stenosis was observed and patient-prosthesis mismatch was identified.Thrombus was reported.Root enlargement surgery was performed and the valve was explanted and replaced.No additional adverse patient effects were reported.
|
| |
|
Additional Manufacturer Narrative
|
|
Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
|
| |
|
Event or Problem Description
|
|
Medtronic received information that five years and nine months following the implant of this transcatheter bioprosthetic valve, valve stenosis was observed and patient-prosthesis mismatch was identified.Thrombus was reported.Root enlargement surgery was performed and the valve was explanted and replaced.No additional adverse patient effects were reported.Additional information was received that the gradient was 37 mmhg when the thrombus was detected.Mild hyperattenuated leaflet thickening and annular calcium were noted.The patient had pre-existing thrombocytopenia, and was on an anticoagulant medication since implant due to atrial fibrillation.No change in the patient's anticoagulant medication was reported.
|
| |
|