Olympus received a literature titled "endoscopic resection of giant esophageal subepithelial lesions: experience from a large tertiary center." background and aims: increased reports on endoscopic resection (er) of esophageal giant subepithelial lesions (g-sels) have emerged in recent years.The aim of this study was to evaluate the efficacy, technical difficulty, and safety through our single-center experience.Methods: seventy-five patients with g-sels undergoing endoscopic resection were included in the training set.Clinicopathologic features, procedure-related characteristics, postprocedural outcomes, and follow-up data were analyzed.A predictive nomogram model for procedural difficulty was proposed based on the multivariable logistic regression analysis.Internal and external validations were conducted to verify the model performance.Results: the overall en bloc resection rate was 93.3%.Intraoperative and postoperative adverse events occurred in 7 (9.3%) and 13 (17.3%) patients, respectively.No recurrence or metastasis was observed.Thirty-two (42.7%) patients underwent a difficult procedure.Age (adjusted odds ratio [aor],.915; p =.004), maximal tumor diameter =8 cm (aor, 9.896; p =.009), irregular shape (aor, 4.081; p =.053), extraluminal growth pattern (aor, 5.419; p =.011), and submucosal tunneling endoscopic resection (aor,.109; p =.042) were found to be statistically or clinically significant factors for predicting endoscopic resection difficulty, based on which a nomogram model was developed.Internal and external validations of the nomogram via receiver-operating characteristic curves and calibration curves achieved favorable results.Conclusions: endoscopic resection serves as a promising therapeutic option for esophageal g-sels.A younger patient age, large tumor size, irregular shape, and extraluminal growth may indicate increased endoscopic resection difficulty, whereas a submucosal tunneling endoscopic resection procedure tends to be of lower difficulty.Our nomogram model performs well for predicting endoscopic resection difficulty for esophageal g-sels.¿type of adverse events/number of patients¿ pneumoperitoneum (7).Pneumothorax/hydrothorax (13).Leaks/fistulas (6).Delayed bleeding (2).Fistula (2).Fever (25).Cardiac mucosal laceration (delayed bleeding) (1).Patient's with pneumoperitoneum required abdominocentesis for decompression.Patient's with pneumothorax/hydrothorax were treated with us-guided thoracic drainage.Patients with leaks or fistulas underwent an endoscopic therapeutic approach.
|
|
This report is being supplemented to provide additional information based on the legal manufacturer's final investigation.The device history record was unable to be reviewed for this device since the serial and/or lot number was not provided.However, olympus only releases products to market that meet all manufacturing specifications and final product release criteria.Based on the results of the investigation, the relationship between the device and the adverse event cannot be confirmed.There was no complaint reported on the subject device.There is no evidence of an olympus device malfunction.Therefore, the root cause cannot be determined.This supplemental report includes additional information received from the author.B5 updated accordingly.Olympus will continue to monitor field performance for this device.
|