LUMINEX CORPORATION VERIGENE BC-GP NUCLEIC ACID TEST KIT; VERIGENE BC-GP ASSAY Back to Search Results
Catalog Number 20-005-018
Medical Device Problem Code No Apparent Adverse Event (3189)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/13/2024
Type of Reportable Event Malfunction
Event or Problem Description
On 5/13/2024 customer (b)(6) medical center reported a discrepant result on bc-gp assay.Verigene detected staphylococcus lugdunensis and enterococcus faecium however culture showed no targets detected.Verigene run 1: staphylococcus ludgunesis and enterococcus faecium detected culture: no targets detected.Data review: per verigene id software requirements specification (toast-srs-1042), in order for an organism to be detected the ic ratio must be greater than or equal to -0.4 and the nc ratio must be greater than 0.85.Review of test cartridge 01864029 shows staphylococcus ludgunesis detected at exposure 1200ms (ic: -0.38 nc: 0.87) and enterococcus faecium detected at exposure 1500ms (ic: -0.4 nc: 087).Pc1 was detected at exposure 24ms (ic: 0.61 nc: 1) and pc 2 was detected at exposure 150ms with ic and nc values of 0.08 and 0.99 respectively.Camera images were clear with minor background and no impact on test results.This was tested on (b)(6) 2024 on sp b3.Consumable review: test cartridge lot: 031824018a.Extraction tray lot: 031124018b.Utility tray lot: 030824018c.There are no ncmrs associated with the lots utilized.There are 22 other erroneous results reported for the staphylococcus ludgunesis target using the lots reported.Due to the amount of complaints, further investigation of test cartridge lot 031824018a will be documented in escalation case (b)(4).Device review: verigene processor sp b3: 20133007.Verigene reader: 18337005.Review of the verigene sp and reader device history was assessed for a time frame of 3 months prior to the reported discrepant result.Verigene processor sp s/n (b)(6) had one pm performed without issue.Verigene reader s/n (b)(6) had one pm performed.There is no indication of a device malfunction.Site performance: a 6-month customer site performance for negative agreement of staphylococcus ludgunesis target was performed from (b)(6) 2024.There was a negative agreement of 99.2% (1605 not detected/1618 expected not detected).Per the verigene gram positive blood culture nucleic acid test package insert (89-30000-00-782) the expected negative agreement for the staphylococcus ludgunesis target is 100% (with a ci of 99.7-99.9).The negative agreement for the enterococcus target was 99.2% (1601 not detected/1614 expected not detected).Per the verigene gram positive blood culture nucleic acid test package insert (89-30000-00-782) the expected negative agreement for the enterococcus faecium target is 100% with a confidence interval of 99.7-100%.Based on the expected performance characteristics and data provided by the customer, the customer site is not performing within the package insert expectations, further investigation of test cartridge lot 031824018a will be documented in escalation case (b)(4).Conclusion through investigation the cause of the reported false positive staphylococcus ludgunesis and enterococcus faecium result will be investigated under (b)(4).Further investigation for root cause will be documented in escalation case (b)(4).The customer site is not performing within the expectations stated in the bc-gp package insert for the staphylococcus ludgunesis target.Although the erroneous result occurred, there was no injury or death to patient.
 
Additional Manufacturer Narrative
Through investigation the cause of the reported false positive staphylococcus ludgunesis and enterococcus faecium result will be investigated under (b)(4).Further investigation for root cause will be documented in escalation case (b)(4).The customer site is not performing within the expectations stated in the bc-gp package insert for the staphylococcus ludgunesis target.Although the erroneous result occurred, there was no injury or death to patient.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VERIGENE BC-GP NUCLEIC ACID TEST KIT
Common Device Name
VERIGENE BC-GP ASSAY
Manufacturer (Section D)
LUMINEX CORPORATION
4088 commercial avenue
northbrook IL 60062
Manufacturer Contact
jordan smith
1224 deming way
madison, WI 53717
MDR Report Key19477876
Report Number3006028115-2024-00003
Device Sequence Number7072531
Product Code PAM
UDI-Device Identifier00840487101575
UDI-Public00840487101575
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
PMA/510(K) Number
K122514
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Other Health Care Professional
Remedial Action Recall
Type of Report Initial
Report Date (Section B) 06/06/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Expiration Date09/16/2024
Device Catalogue Number20-005-018
Device Lot Number031824018A
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer Not provided
Initial Report FDA Received Date06/06/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured03/18/2024
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-