Model Number NV-10-30-HELIX
Medical Device Problem Code Physical Resistance/Sticking (4012)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/14/2024
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
H3: product analysis of nv-10-30-helix, lotno:226905955 as found condition: the concerto device was returned for analysis within shipping box; within sealed plastic biohazard pouch; within an opened concerto inner pouch within a dispenser coil and within an introducer sheath.The unknown micro catheter used during the event was not returned for analysis.Visual inspection/damage location details: no damages or irregularities were found with the introducer sheath.The pusher was found bent at ~127.0cm from the proximal end.The pusher was found broken at ~134.3cm from the proximal end with the two segments retained by the release wire (figure f).The location of the break was just outside the distal introducer sheath.The coin was found retracted out of the lumen stop.The concerto implant coil was already detached and not returned for analysis.Testing/analysis: the concerto coil could not be used for resistance testing as the implant was already detached.Conclusion: based on the device analysis and reported information, the customer¿s report of ¿coil resistance/stuck in catheter¿ could not be confirmed but could not be ruled out.Possible causes for coil resistance in catheter are, but not limited to, lack of hydration before procedure, user does not maintain sufficient continuous flush, damaged micro catheter, incompatible micro catheter, or tortuous anatomy.Customer only reported devices were prepared per ifu.Therefore, the likely cause could not be determined.As the unknown micro catheter used in the event was not returned for analysis, any contribution of the micro catheter towards the resistance could not be determined.As the model and lot numbers were not reported, compatibility could not be assessed.The pusher was found bent, potentially due to advancing against the reported resistance.The pusher was found broken, detaching the implant as expected by the detachment subassemblies.Due to the location of the break, it is possible that the pusher became kinked and then became stuck at the distal introducer sheath during retracting, causing the pusher to break.Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
 
Event or Problem Description
Medtronic received a report that the concerto coil was being used as per the ifu but the coil did not pass through the microcatheter that was used in the procedure.A new medtronic device was used to complete the procedure.The reported device and any accessory devices were prepared as indicated in the instructions for use (ifu).No patient symptoms or further complications were reported as a result of this event.Additional information received reported the catheter was not a medtronic device.No other information was known or available.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CONCERTO NYLON
Common Device Name
DEVICE, VASCULAR, FOR PROMOTING EMBOLIZATION
Manufacturer (Section D)
MEDTRONIC MEXICO
av. paseo del cucapah #10510
tijuana,bc 22570
MX  22570
Manufacturer (Section G)
MEDTRONIC MEXICO
av. paseo del cucapah #10510
tijuana,bc 22570
MX   22570
Manufacturer Contact
glen belmer
9775 toledo way
irvine, CA 92618
6122713209
MDR Report Key19520190
Report Number9612164-2024-02793
Device Sequence Number8540834
Product Code KRD
UDI-Device Identifier00847536044999
UDI-Public00847536044999
Combination Product (Y/N)N
Initial Reporter CountryKS
PMA/510(K) Number
K090046
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative,Distributor
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 06/12/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date07/04/2026
Device Model NumberNV-10-30-HELIX
Device Catalogue NumberNV-10-30-HELIX
Device Lot Number226905955
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/24/2024
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/18/2024
Initial Report FDA Received Date06/12/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured07/04/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-