Catalog Number 9927610001
Medical Device Problem Code Dull, Blunt (2407)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/20/2024
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.The manufacturer internal reference number is: (b)(4).Reflects all related report numbers associated with this product event that have been submitted at this time.
 
Event or Problem Description
A physician reported that during surgery it was found that knives were dull.Used slit knife separately and completed the surgery with no patient harm.Procedure details was not reported.
 
Additional Manufacturer Narrative
Corrected information is provided in d.4.Two opened knives, in sheathing, in bag were received for the report of slit knife was dull.Samples were visually inspected and found to be conforming.Functional penetration testing was performed and sample one was conforming.Sample two was nonconforming.A review of the device history record traceable to the reported lot number, indicates that the reported product was processed and released according to the reported product¿s acceptance criteria.The returned opened sample two was found to be functionally nonconforming, therefore the dull blade was confirmed.The root cause for the dull cutting edge is related to the electropolishing step in the manufacturing process.The returned opened sample one was found to be visually and functionally conforming, therefore dull blades as described in the complaint was not confirmed and a root cause cannot be determined for the complaint as described by the customer.A nonconformance investigation is currently in progress to investigate the failed penetration testing for cutting instruments and the root cause of the nonconforming penetration value of the cutting instruments.All knives are 100% inspected by trained operators using a minimum of 10x magnification during manufacturing.Functional penetration testing is performed and monitored during the finishing process to ensure the sharpness of the product.Complaints are reviewed and monitored at regular intervals for any significant adverse trends.The manufacturer internal reference number is: (b)(4).H.10 reflects all related report numbers associated with this product event that have been submitted at this time.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
A-OK OPHTHALMIC KNIVES
Common Device Name
KNIFE, OPHTHALMIC
Manufacturer (Section D)
ALCON RESEARCH, LLC - ALCON PRECISION DEVICE
714 columbia avenue
sinking spring PA 19608
Manufacturer (Section G)
ALCON RESEARCH, LLC - ALCON PRECISION DEVICE
714 columbia avenue
sinking spring PA 19608
Manufacturer Contact
jonathan schlech
6201 south freeway
mail stop ab2-6
fort worth, TX 76134
8007579780
MDR Report Key19582092
Report Number2523835-2024-01495
Device Sequence Number7317796
Product Code HNN
UDI-Device Identifier00380659927614
UDI-Public00380659927614
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 09/25/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number9927610001
Device Lot Number167PWV
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 05/27/2024
Supplement Date Received by Manufacturer08/28/2024
Initial Report FDA Received Date06/21/2024
Supplement Report FDA Received Date09/25/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured09/26/2023
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
A-OK OPHTHALMIC KNIVES; CUSTOM-PAK SURGICAL PROCEDURE PACK; CUSTOM-PAK SURGICAL PROCEDURE PACK
Patient SexUnknown
-
-