|
This complaint is from a literature source.The following literature cite has been reviewed: tijskens m, abugattas jp, thoen h, strazdas a, schwagten b, wolf m, de greef y.Adding electroanatomical mapping to cryoballoon pulmonary vein isolation improves 1-year clinical outcome and durability of pulmonary vein isolation: a propensity score-matched analysis.J cardiovasc dev dis.2024 feb 6;11(2):57.Doi: 10.3390/jcdd11020057.Pmid: 38392271; pmcid: pmc10889252.Objective/methods/study data: background: adding electroanatomical left atrial (la) voltage mapping to cryoballoon ablation (cba) improves validation of acute pulmonary vein isolation (pvi).Aims: to determine whether the addition of mapping can improve outcome and pvi durability.Methods: one-year outcome and pv reconnection (pvr) rate at first repeat ablation were studied in 400 af patients in a propensity-matched analysis (age, af type, cha2ds2-vasc score) between achieve catheter-guided cba with additional ensite la voltage maps performed pre- and post-cba (mapping group; n = 200) and ct- and achieve catheter-guided cba (control group; n = 200).Clinical success was defined as freedom of documented af or atrial tachycardia (at) > 30 s.Pv reconnection patterns were characterized in repeat ablations.Results: at 1 year, 77 (19.25%) patients had recurrence of af/at, significantly lower than in the mapping group: 21 (10.5%) vs.56 (28%), p < 0.001.Procedure time was shorter (72.2 ± 25.4 vs.78.2 ± 29.3 min, p = 0.034) and radiation exposure lower (4465.0 ± 3454.6 gy.Cm2 vs.5940.5 ± 4290.5 gy.Cm2, p = 0.037).Use of mapping was protective towards af/at recurrence (hr = 0.348; 95% ci 0.210-0.579; p < 0.001), independent of persistent af type (hr = 1.723; 95% ci 1.034-2.872; p = 0.037), and la diameter (hr = 1.055; 95% ci 1.015-1.096; p = 0.006).At repeat ablation (n = 90), persistent complete pvi was seen in 14/20 (70.0%) versus 23/70 (32.9%) in the mapping and conventional group, respectively (p = 0.03).Reconnection rate of the right inferior pv was lower with mapping (10.0% vs.34,3%, p = 0.035).Conclusions: adding electroanatomical la voltage mapping to cba improves 1-year clinical outcome and lowers both procedure time and radiation exposure.At repeat, use of mapping increases complete persistent pvi mainly by improving pvi durability of the ripv.Lot, model and catalog number are not available, but the suspected biosense device possibly associated with reported adverse events: pentaray concomitant biosense webster devices that were used in this study: lasso, carto 3 system concomitant non-biosense webster devices that were also used in this study: ensite¿cardiac mapping system (abbott inc., st.Paul, mn, usa), 8-polar inner-lumen spiral mapping catheter (achieve¿, medtronic inc., minneapolis, mn, usa), 15-fr steerable sheath (flex cath 18 advance¿, medtronic inc., minneapolis, mn, usa), 28-mm cb (arctic front advance¿), high-density mesh mapper (bard electrophysiology, lowell, ma, usa) adverse event(s) and provided interventions possibly associated with unidentified pentaray that occurred in mapping group: qty 1: stroke (cerebrovascular accident) (recognized procedural complication) (adverse event) qty 2: (pericarditis) (recognized procedural complication) (adverse event) qty 1: transient air embolism (air embolism) (recognized procedural complication) (adverse event).
|
|
This complaint is from a literature source.The following literature cite has been reviewed: tijskens m, abugattas jp, thoen h, strazdas a, schwagten b, wolf m, de greef y.Adding electroanatomical mapping to cryoballoon pulmonary vein isolation improves 1-year clinical outcome and durability of pulmonary vein isolation: a propensity score-matched analysis.J cardiovasc dev dis.2024 feb 6;11(2):57.Doi: 10.3390/jcdd11020057.Pmid: 38392271; pmcid: pmc10889252.No device was received for analysis at the time of submission of the initial 3500a.Since the product was not returned for analysis, no product failure analysis can be conducted, and no determination of possible contributing factors could be made.Device history record (dhr) review cannot be conducted because no lot number was provided by the customer.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by biosense webster, inc., or its employees that the report constitutes an admission that the product, biosense webster, inc., or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Manufacturer's ref # (b)(4).
|