• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ALCON RESEARCH, LLC - HUNTINGTON ACRYSOF IQ PANOPTIX TRIFOCAL IOL; LENS, MULTIFOCAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ALCON RESEARCH, LLC - HUNTINGTON ACRYSOF IQ PANOPTIX TRIFOCAL IOL; LENS, MULTIFOCAL Back to Search Results
Model Number TFNT00
Medical Device Problem Codes Scratched Material (3020); Failure to Eject (4010)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/22/2024
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.The manufacturer internal reference number is: (b)(4).H.10 reflects all related report numbers associated with this product event that have been submitted at this time.
 
Event or Problem Description
A non-healthcare professional reported during an intraocular lens (iol) implant procedure, the intraocular lens got stuck in the cartridge and scratched the optical zone of the lens.Additional information has been received and stated that the lens was removed during initial procedure and replaced with another lens.There was no patient harm.
 
Additional Manufacturer Narrative
Additional information was provided in the product was not returned.Two photos were provided of the lens.The lens appeared to be cut or cracked from the edge to the center in a v shape pattern.Unable to discern scratches in the photos.Product history records were reviewed and the documentation indicated the product met release criteria.The account indicated the use of a qualified cartridge with a non-qualified handpiece and viscoelastic.The root cause is most likely related to a failure to follow the ifu.The account used an unqualified lens, cartridge, handpiece, viscoelastic combination.Company foldable intraocular lens (iols) are qualified for use with a company qualified delivery system (handpiece and cartridge) and ophthalmic viscosurgical device (ovd) combination.The use of an unqualified combination may cause damage to the iol and potential complications during the implantation process.Due diligence has been performed in an attempt to obtain further information on this event.The account indicated the product was not available to evaluate.File will be reopened if new information is received.The manufacturer internal reference number is: (b)(4).H.10 reflects all related report numbers associated with this product event that have been submitted at this time.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ACRYSOF IQ PANOPTIX TRIFOCAL IOL
Common Device Name
LENS, MULTIFOCAL
Manufacturer (Section D)
ALCON RESEARCH, LLC - HUNTINGTON
6065 kyle lane
huntington WV 25702
Manufacturer (Section G)
ALCON RESEARCH, LLC - HUNTINGTON
6065 kyle lane
huntington WV 25702
Manufacturer Contact
jonathan schlech
6201 south freeway
mail stop ab2-6
fort worth, TX 76134
8007579780
MDR Report Key19612928
Report Number1119421-2024-01211
Device Sequence Number15029052
Product Code MFK
UDI-Device Identifier00380652357784
UDI-Public(01)00380652357784(17)280515(11)230518(10)15644502(21)15644502049
Combination Product (Y/N)N
Initial Reporter CountryBR
PMA/510(K) Number
P040020
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 09/16/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberTFNT00
Device Catalogue NumberTFNT00.225
Device Lot Number15644502
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 05/31/2024
Supplement Date Received by Manufacturer08/19/2024
Initial Report FDA Received Date06/26/2024
Supplement Report FDA Received Date09/16/2024
Date Device Manufactured05/18/2023
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
INJECTOR:EPSILON.; MONARCH III CARTRIDGE D.; OCUCOAT.
Patient Age67 YR
Patient SexFemale
-
-