• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ARTHREX, INC. FIBERTAK DISPOSABLES CURVED KIT; ORTHOPEDIC MANUAL SURG INSTR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARTHREX, INC. FIBERTAK DISPOSABLES CURVED KIT; ORTHOPEDIC MANUAL SURG INSTR Back to Search Results
Model Number FIBERTAK DISPOSABLES CURVED KIT
Medical Device Problem Code Device Dislodged or Dislocated (2923)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/30/2024
Type of Reportable Event Malfunction
Event or Problem Description
On (b)(6) 2024 it was reported by a sales representative via phone that an ar-3600-2 fibertak suture anchor and an ar-3638dc knotless fibertak disposable kit, curved had an issue during a shoulder rotator cuff repair procedure with biceps tenodesis on (b)(6) 2024.The surgeon put the drill guide on, drilled and inserted the suture anchor through the drill guide, when a plastic part of the anchor inserter that was outside of the patient broke off inside the drill guide.The inserter could not be removed from the drill guide, they had fused together.When removing the inserter together with the drill guide from the patient, the knotless suture anchor was pulled out as well.Nothing broke off inside the patient, the broken plastic piece was contained within the drill guide and everything was removed.The same spot was used, the hole was made bigger and an ar-1927psf-475 suture anchor, peek corkscrew ft with an unknown lot number was used to complete the procedure successfully with no harm to the patient.There was no case delay reported, and no additional anesthesia was administered.The complaint devices were discarded, but pictures were taken.This occurred during use with no reported patient harm.
 
Additional Manufacturer Narrative
The contribution of the device to the reported event could not be determined as the device was not returned for evaluation.The root cause of the event could not be determined from the information available and without device evaluation.If the device becomes available for evaluation, a follow-up report will be submitted.
 
Additional Manufacturer Narrative
The complaint allegation is confirmed based on the customer-provided pictures.Visual evaluation of the customer-provided pictures noted an ar-3638dc knotless fibertak disposable kit, curved broke off inside the drill guide.Refer to attachments.Based on the information provided, arthrex was able to conclude a most likely cause.The most likely cause for the reported failure can be attributed to user error of the device due to excessive force being used during insertion of the implant.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FIBERTAK DISPOSABLES CURVED KIT
Common Device Name
ORTHOPEDIC MANUAL SURG INSTR
Manufacturer (Section D)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer (Section G)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer Contact
jared engle
8009337001
MDR Report Key19614139
Report Number1220246-2024-06422
Device Sequence Number14987712
Product Code LXH
UDI-Device Identifier00888867287433
UDI-Public00888867287433
Combination Product (Y/N)N
Initial Reporter StateID
Initial Reporter CountryUS
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Distributor
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date (Section B) 07/01/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberFIBERTAK DISPOSABLES CURVED KIT
Device Catalogue NumberAR-3638DC
Device Lot Number15122912
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/31/2024
Supplement Date Received by Manufacturer06/06/2025
Initial Report FDA Received Date06/26/2024
Supplement Report FDA Received Date07/01/2025
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured08/01/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-