EXACTECH, INC. LGC TIBIAL FIT TRAY CEM SZ 6F / 6T; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL
|
Back to Search Results |
|
| Catalog Number |
02-012-45-6060 |
| Medical Device Problem Codes |
Unstable (1667); Loss of Osseointegration (2408); Loosening of Implant Not Related to Bone-Ingrowth (4002)
|
| Health Effect - Clinical Codes |
Failure of Implant (1924); Pain (1994); Synovitis (2094); Osteolysis (2377); Ambulation or Postural Difficulties (2544); Joint Laxity (4526); Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581); Joint effusion (4849)
|
| Date of Event |
05/20/2020
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
H10.Related cases: mfr #1038671-2023-00155 report 1 of 3.Report 3 of 3.H11.Additional manufacturer narrative- report 2 of 3.D10.Concomitants: 1332936 204-26-13 - ps tibial inserts sz 6, 13mm 2977817 200-02-41 - three peg patella 41mm 3553937 204-34-04 - fluted stem extension 40l x 14 mm 3703978 204-70-00 - tibial stem ext.Screw 2057579 234-03-06 - optetrak asy,ps cemented femoral, sz 6, h3.The revision reported was likely the result of prosthesis wear, osteolysis, and insufficient bonds between the devices and the bones, which led to aseptic (non-infected) loosening.It is possible that a contributing factor to the reported wear may have been the result of being packaged in a non-conforming bag for more than 5 years before it was implanted.The extent and root cause of the osteolysis, loosening, and prosthesis wear could not be determined as the devices were not returned for evaluation, and images and radiographs were not provided.This is considered ¿very low¿ occurrence rate and therefore, this issue does not appear to be design-related.The dhr for this tibial tray was reviewed, and all components were accepted with conformance to the device requirements.The risk documents were reviewed, and the risk is captured.These devices are used for treatment not diagnosis.There is no additional information available.
|
| |
|
Event or Problem Description
|
|
It was reported via a legal notification, that the patient, underwent an initial right knee replacement surgery and then approximately 5 years 5 months post initial procedure the patient was revised.Revision operative report-preoperative diagnosis: failed right total knee arthroplasty.Findings: massive osteolysis, loose tibial component.There was a tremendous amount of fluid about the knee consistent with known particulate disease and synovitis.There was osteolysis about the femoral implant, there was an are tunneling into the posterolateral femoral condyle, this was debrided.The tibia was grossly loose with a large defect within the medial tibia.There was additional bone loss posterolaterally which created a cortical defect in the posterolateral through which muscle came through.The medial side was absent good bone.The patella was grossly loose and was removed.¿the patient was taken to the postanesthesia care unit in stable condition.He tolerated the procedure well.There were no immediate complications.¿ there is no additional information available.
|
| |
|
Additional Manufacturer Narrative
|
|
The reason for the revision reported cannot be confirmed from the information provided but may be the result of prosthesis wear, instability, tibial loosening, and patellar loosening.Or due to inclusion of the polyethylene in the packaging recall.Additionally, a contributing factor to the reported wear may have been the result of being packaged in a non-conforming vacuum bag for more than five years.Potential contributions of user and patient-related considerations to the event could not be assessed as the devices were not available for evaluation and images and radiographs were not provided.If any further information is obtained that would change or alter any information provided, a supplemental report will be filed accordingly.
|
| |
|