(b)(4).Date sent: 7/3/2024.D4: batch # unk.This report is related to a journal article; therefore, no product will be returned for analysis and the batch history records cannot be reviewed as the lot/batch number has not been provided.Attempts are being made to obtain the following information.To date no response has been provided.If further details are received at a later date a supplemental medwatch will be sent.Does the author/surgeon believe that the ethicon devices mentioned in this article caused/contributed to the reported events in the article? this report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
|
|
Title : a cooperative approach for treatment of zenker's diverticulum.Authors : daniel castaneda, francisco franco azar,ishtiaq hussain, luis f.Lara, ronnie r.Pimente,gilberto alemar,candace hrelec,jefrey ponsky, tolga erim citations : surgical endoscopy.Pages : 1-7.Https://doi.Org/10.1007/s00464-021-08736-z.The aim of this study was to evaluate the efficacy, failure rate, and safety profile of a cooperative approach by a gastroenterologist and otolaryngologist in the treatment of zenker¿s diverticulum.Single-center retrospective study of patients ( n=63 ) who underwent a cooperative endoscopic diverticulectomy by a gastroenterologist and otolaryngologist at cleveland clinic florida between 2012 and 2019.Patients were predominantly males (63.5%) and white (84.1%), with mean age 73.5 years (53¿95).Most subjects presented dysphagia (98.4%), mostly to solids (79.4%).An endopath 45 stapler (ethicon endo-surgery, cincinnati, oh, usa) was engaged onto the muscular bar and subsequently fired.If no muscular bar division was achieved, a harmonic endoscopic scalpel was used to cut the tissue or endopath scissors were used to cut the midline of the stapler and a second stapling pass was performed as mentioned before.In conclusion, a cooperative endoscopic approach by gastroenterology and otolaryngology for symptomatic zenker¿s diverticulum management offered excellent technical and clinical success.This approach proved to be safe and effect.
|