• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ARTHREX, INC. KNOTLESS DIS CLAV PLATE BUTTON TIGHTROP; BONE FIXATION PLATE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARTHREX, INC. KNOTLESS DIS CLAV PLATE BUTTON TIGHTROP; BONE FIXATION PLATE Back to Search Results
Model Number KNOTLESS DIS CLAV PLATE BUTTON TIGHTROP
Medical Device Problem Code Detachment of Device or Device Component (2907)
Health Effect - Clinical Code Insufficient Information (4580)
Date of Event 06/12/2024
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Investigation is in process.A follow-up report will be provided upon availability of additional information.
 
Event or Problem Description
On 06/13/2024, it was reported by a sales representative via sems-(b)(4) that an ar-2658tr suture anchor and an ar-2372blo knotless ac tightrope® open repair implants buttons popped off of the inserter and they weren't able to screw then back on.This occurred during an ac joint repair on (b)(6) 2024.
 
Event or Problem Description
Additional information was provided on 06/18/2024 when the sales representative stated that the buttons had come off both devices prematurely.They were able to retrieve them.They used the drill that came in the kit to prepare both bone tunnels.The patient had good bone quality.They used a cerclage fiber tape suture to proceed.
 
Additional Manufacturer Narrative
Additional information: g3, h3, h6.Complaint allegation is not confirmed.Based on the information provided, which may include the device (if available and returned), pictures, videos, event description, and any additional information from the field, arthrex was able to conclude a most likely cause.Per surgical technique lt1-02553-e 3-insert the coracoid button into the clavicle tunnel.Light taps on the inserter handle can aid in advancing the button through the tunnels.4-insert the coracoid button through the clavicle and the coracoid tunnel.Fluoroscopy may be used to confirm proper button alignment and that it extends below the inferior cortex of the coracoid.The most likely cause for the reported failure can be attributed to user error of the device due to misalignment insertion, and/or prying/leveraging of the device during insertion.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
KNOTLESS DIS CLAV PLATE BUTTON TIGHTROP
Common Device Name
BONE FIXATION PLATE
Manufacturer (Section D)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer (Section G)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer Contact
jared engle
8009337001
MDR Report Key19689787
Report Number1220246-2024-06620
Device Sequence Number15484479
Product Code HRS
UDI-Device Identifier00888867271814
UDI-Public00888867271814
Combination Product (Y/N)N
Initial Reporter StateNC
Initial Reporter CountryUS
PMA/510(K) Number
K143139
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Distributor
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 04/03/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberKNOTLESS DIS CLAV PLATE BUTTON TIGHTROP
Device Catalogue NumberAR-2658TR
Device Lot Number15158627
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 06/13/2024
Supplement Date Received by Manufacturer06/18/2024
03/17/2025
Initial Report FDA Received Date07/08/2024
Supplement Report FDA Received Date12/18/2024
04/03/2025
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured10/25/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-