| Catalog Number |
515306 |
| Medical Device Problem Code |
Device Contamination with Chemical or Other Material (2944)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
07/09/2024
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
Met with (b)(6) to further understand the pir's below: (b)(6).(b)(6) are experiencing a "foreign matter" in the iv bags, it looks small and white with a potential plastic nature.She is unsure where this is coming from, possibly phaseal? (b)(6) bought along some of the bags with the "foreign matter".We looked for a good 20 minutes trying to find this matter, i was able to identify one which i took photos of.The rest i could not identify, but it is so small that it's hard to see.It's mainly with trastuzumab (grey vial bung) and rituximab (grey vial bung) but can occur with other drugs.Its happening in baxter pvc and non pivc bag.No drawing up needle used.They have a strict inspection policy for looking for foreign matter, in all cases it has not occured until they attach injector (515003) to the bag adapter (515306).So they check the syringe before injecting into bag and aren't seeing the matter.
|
| |
|
Additional Manufacturer Narrative
|
|
Initial mdr submission.A follow up mdr will be submitted if additional information, a device evaluation, or a device history review is completed.The actual date of event is unknown.The date received by manufacturer was entered into the date of event field.
|
| |
|
Additional Manufacturer Narrative
|
|
Following the submission of the initial mdr, it was noted that the following corrections were needed.Corrections: medical device brand name corrected.Material number corrected.510k correccted.
|
| |
|
Event or Problem Description
|
|
Material number being updated.
|
| |
|
Additional Manufacturer Narrative
|
|
(b)(4).Follow up mdr for device evaluation: multiple iv bags with the infusion adapter attached were provided to our quality team for investigation.Through visual inspection, particles were observed within the iv bag.The particles appeared white in color and based on visual characteristics, it is believed to be small particles of the phaseal membrane.Unfortunately, we were not able to safely extract the particles, therefore the specific composition cannot be identified at this time.Fragmentation testing is performed according to procedure, to evaluate any particulates generated by the injector when mated to other components after ten activations.As a lot number was unavailable for this incident, a device history record review could not be completed.While phaseal needles and spikes are designed to reduce coring, there are several factors that may impact coring tendency.Coring from the membrane may occur due to fragmentation caused by multiple injections or excessive welding of the membrane.Coring of the rubber stopper may result depending on the stopper quality, the design and dimensions of the needles used.Based on the available information, we are not able to identify a root cause related to the manufacturing process at this time.Complaints received for this device and reported condition will continue to be tracked and trended for future occurrence.
|
| |
|
Event or Problem Description
|
|
No additional information.
|
| |
|