| Catalog Number |
03.010.063 |
| Medical Device Problem Code |
Device-Device Incompatibility (2919)
|
| Health Effect - Clinical Code |
Insufficient Information (4580)
|
| Date of Event |
06/28/2024
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Product complaint (b)(4).Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.H11 additional narrative: investigation summary: d4: udi: as the lot and serial number for the device involved in the event was not provided, the full udi is currently not available.D9: complainant part is not expected to be returned for manufacturer review/investigation.H3, h4, h6: without a lot number the device history records review could not be completed.Product was not returned.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.If additional information is made available, the investigation will be updated as applicable device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Event or Problem Description
|
|
It was reported that on (b)(6) 2024, the patient underwent orif surgery for fracture of the proximal humerus on proximal humerus with the products in question.In the surgery, during the drilling of the distal lateral stop, the drill bits in question were not sharp enough, although the patient's bone quality was also a factor.The sleeve in question was inserted and drilled until it contacted the bone, avoiding the soft tissue, but the drill interfered in the g-hole.The image confirmed that the drill tip reached inside the nail hole, so when the drill tip was lightly tapped with a hammer, the drill tip passed through the hole.Finally, when inserting the end cap in question, the end cap was reinserted several times, but it did not engage properly, and the surgeon decided to close the wound with the cap engaged at an angle.The surgery was completed successfully with a 30 minutes surgical delay.No further information is available at this time.This report is for one (1) protect sleeve 12/8 l188.This is report 3 of 6 for complaint (b)(4).
|
| |
|
Search Alerts/Recalls
|
|