Catalog Number AA6316
Medical Device Problem Code Burst Container or Vessel (1074)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 06/01/2024
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
B3: estimated date.
 
Event or Problem Description
According to the available information, during patient indwelling, the balloon burst and fell out.
 
Additional Manufacturer Narrative
Two used samples were received.After desinfection we can observed that these balloons were burst without missing part.Burst issue of silicone balloon is known but according to the available information we cannot conclude on a specific root cause in this case.After receiving this complaint, we searched for other complaints and we found none regarding the lot number 9362253.Quality database was checked and revealed a corrective and preventive action: capa-000152."balloon issues on folysil and silicone prostatic catheters" was opened and monthly monitoring.No corrective action will be implemented as our trend is not increasing and the threshold is not exceeded.The evaluation has showed that risks are adequately controlled and reduced as far as possible in the state of art.Based on this, we can conclude that residual risks are adequately controlled and reduced as far as possible, and the residual risks associated with the use of the product are acceptable when weighed against the benefits to the patient/user.It is concluded that the risks identified are still acceptable and considered as safe.
 
Event or Problem Description
According to the available information, during patient indwelling, the balloon burst and fell out.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FOLYSIL SILICONE CATHETER
Common Device Name
INDWELLING URETHRAL DRAINAGE BALLOON CATHETER, NON-ANTIMICROBIAL
Manufacturer (Section D)
COLOPLAST A/S
1 holtedam humlebaek, dk 3050
humlebaek 3050
DA  3050
Manufacturer Contact
usbes brian schmidt
1601 west river road n
minneapolis, MN 55411
MDR Report Key19822786
Report Number9610711-2024-00190
Device Sequence Number12908792
Product Code EZL
UDI-Device Identifier03600040128770
UDI-Public03600040128770
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K233411
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 12/31/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue NumberAA6316
Device Lot Number9362253_AA63161002
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer Not provided
Supplement Date Received by ManufacturerNot provided
Initial Report FDA Received Date07/24/2024
Supplement Report FDA Received Date12/31/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured09/08/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-