Catalog Number 4100110000
Medical Device Problem Code Detachment of Device or Device Component (2907)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 06/30/2024
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
This record is a consolidation of records summarized as a part of the fda voluntary malfunction summary reporting program.Reported events 5 events were reported for this quarter.Product return status 2 devices were received.1 device was not available for evaluation.2 device investigation types have not yet been determined.Additional information 5 devices were not labeled for single-use.5 devices were not reprocessed or reused.
 
Event or Problem Description
This report summarizes 5 malfunction events in which the device had a component detach.- 5 events had no patient involvement; no patient impact.
 
Additional Manufacturer Narrative
This record is a consolidation of records summarized as a part of the fda voluntary malfunction summary reporting program.Supplemental rationale.Corrected data: b5, h1, h6, h11.5 events were previously reported during the reporting quarter; however, - 2 events were reported in error.- 3 previously reported events are included in this follow-up record.Product return status 2 devices were received.1 device was not available for evaluation.
 
Event or Problem Description
This report summarizes 3 malfunction events in which the device had a component detach.3 events had the problem identified during a non-clinical procedure; there was no patient involvement.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AO SMALL DRILL
Common Device Name
INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT
Manufacturer (Section D)
STRYKER INSTRUMENTS-A DIVISION OF STRYKER CORP
1941 stryker way
portage MI 49002
Manufacturer (Section G)
STRYKER INSTRUMENTS-KALAMAZOO
4100 east milham avenue
kalamazoo MI 49001
Manufacturer Contact
kelsey barla
1941 stryker way
portage, MI 49002
2693237700
MDR Report Key19823266
Report Number3015967359-2024-01561
Device Sequence Number21002602
Product Code HWE
UDI-Device Identifier04546540068156
UDI-Public04546540068156
Combination Product (Y/N)N
Initial Reporter StateMI
Initial Reporter CountryUS
Number of Events Summarized3
Summary Report (Y/N)Y
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 01/27/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Catalogue Number4100110000
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 06/30/2024
Supplement Date Received by Manufacturer06/30/2024
Initial Report FDA Received Date07/24/2024
Supplement Report FDA Received Date01/27/2025
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Reuse
Patient Sequence Number1
Patient SexUnknown
-
-