• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: AOMORI OLYMPUS CO., LTD. DISPOSABLE DISTAL ATTACHMENT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

AOMORI OLYMPUS CO., LTD. DISPOSABLE DISTAL ATTACHMENT Back to Search Results
Model Number D-201-11804
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Hemorrhage/Blood Loss/Bleeding (1888)
Date of Event 02/15/2024
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
This report is being supplemented to provide additional information based on the legal manufacturer's final investigation.The device history record was unable to be reviewed for this device since the serial and/or lot number was not provided.However, olympus only releases products to market that meet all manufacturing specifications and final product release criteria.Based on the results of the investigation, a relationship between the device and the adverse event cannot be confirmed.There was no complaint reported on the subject device.There is no evidence of an olympus device malfunction.Therefore, the root cause cannot be determined.Olympus will continue to monitor field performance for this device.
 
Event or Problem Description
Olympus medical systems corp.(omsc) reviewed a literature titled "endoscopic resection of gastric gastrointestinal stromal tumor using clip-and-cut endoscopic full-thickness resection: a single-center, retrospective cohort in korea".Literature summary background/aims: to overcome the technical limitations of classic endoscopic resection for gastric gastrointestinal stromal tumors (gists), various methods have been developed.In this study, we examined the role and feasibility of clip-and-cut procedures (clip-and-cut endoscopic full-thickness resection [cc-eftr]) for gastric gists.Methods: medical records of 83 patients diagnosed with gists after endoscopic resection between 2005 and 2021 were retrospectively reviewed.Moreover, clinical characteristics and outcomes were analyzed.Adverse events a total of 43 (51.8%) patients experienced adverse events after er (table 5).The overall rates of adverse events were higher in the cc-eftr group compared to that in the esd group (37.3% for esd vs.75.0% for cc-eftr, p=0.001).Pneumoperitoneum occurred in 13 (25.5%) and 22 (68.8%) patients in the esd and cc-eftr groups, respectively.However, only one patient in the esd group and two in the cc-eftr group progressed to localized peritonitis, however, they recovered after conservative care, including broad-spectrum antibiotic administration (2.0% for esd vs.6.3% for cc-eftr, p=0.311).Two patients underwent emergent operations during the er.In the esd group, a patient with severe bleeding during the procedure underwent emergent wedge resection.In the cc-eftr group, a patient with failed endoscopic closure for a huge transmural hole during er underwent emergent wedge resection.All other patients were managed with conservative treatment, including endoscopic closure with hemostatic clips and intravenous antibiotics, without any further adverse events.Results: endoscopic submucosal dissection (esd) and cc-eftr were performed in 51 and 32 patients, respectively.The gists were detected in the upper third of the stomach for esd (52.9%) and cc-eftr (90.6%).Within the cc-eftr group, a majority of gists were located in the deep muscularis propria or serosal layer, accounting for 96.9%, as opposed to those in the esd group (45.1%).The r0 resection rates were 51.0% and 84.4% in the esd and cc-eftr groups, respectively.Seven (8.4%) patients required surgical treatment (six patients underwent esd and one underwent cc-eftr,) due to residual tumor (n=5) and post-procedure adverse events (n=2).Patients undergoing r0 or r1 resection did not experience recurrence during a median 14-month follow-up period, except for one patient in the esd group.Conclusions: cc-eftr displayed a high r0 resection rate; therefore, it is a safe and effective therapeutic option for small gastric gists.Type of adverse events/number of patients: adverse event 1 (bleeding - female, 63).Adverse event 2 (perforation - male, 72).Adverse event 3 (fever -20 patients, pneumoperitoneum -35 patients, peritonitis -3 patients).
 
Additional Manufacturer Narrative
This report is related to the following linked patient identifiers: adverse event 1 ((b)(6).This mdr is for adverse event 1.Since the literature described "d-201-11814", olympus selected "d-201-11804" as a representative product.The product was unknown, but a representative product was chosen for processing purposes.The evaluation of the event is ongoing.Should additional relevant information become available, a supplemental report will be submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DISPOSABLE DISTAL ATTACHMENT
Common Device Name
DISPOSABLE DISTAL ATTACHMENT
Manufacturer (Section D)
AOMORI OLYMPUS CO., LTD.
2-248-1 okkonoki
kuroishi-shi, aomori 036-0 357
JA  036-0357
Manufacturer (Section G)
AOMORI OLYMPUS CO., LTD.
2-248-1 okkonoki
kuroishi-shi, aomori
Manufacturer Contact
todd brill
800 west park drive
westborough, MA 01581
5082077661
MDR Report Key19839584
Report Number9614641-2024-01510
Device Sequence Number7675971
Product Code FDS
UDI-Device Identifier04953170278280
UDI-Public4953170278280
Combination Product (Y/N)N
Initial Reporter CountryKS
PMA/510(K) Number
K984358
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Study,Literature,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 08/28/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model NumberD-201-11804
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/02/2024
Supplement Date Received by Manufacturer08/28/2024
Initial Report FDA Received Date07/26/2024
Supplement Report FDA Received Date08/28/2024
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age63 YR
Patient SexFemale
-
-