DENTSPLY IMPLANTS MANUFACTURING GMBH ANK STAND C/ ABUT B/3/4STRAI; IMPLANT, ENDOSSEOUS, ROOT-FORM Back to Search Results
Catalog Number 31021110
Medical Device Problem Code Fracture (1260)
Health Effect - Clinical Code Failure of Implant (1924)
Date of Event 12/14/2023
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that a patient experienced a dental implant loss.
 
Additional Manufacturer Narrative
Therefore, because a serious injury resulted, this event is reportable per 21 cfr part 803.Section h6 was done based on the information provided by the initial reporter and our long-time experience in the investigation of similar complaints.Product return is requested and product will be evaluated after receipt.In case any new or additional information will be gained from this investigation a follow-up report will be sent.Trend is tracked and monitored.
 
Additional Manufacturer Narrative
Additional fda coding being added after investigation of device.Adding additional type of investigation code 10.This is a follow up report to add this additional code.Additional fda coding being added after investigation of device.Adding investigation findings: 3243.This is a follow up report to add this additional code.Additional fda coding being added after investigation of device.Adding investigation conclusions: 50.This is a follow up report to add this additional code.Device received for this event is being corrected from ank bal postc/3strai catalog # 17-3153 to ank stand c/ abut b/3/4strai catalog # 31021110.This is a follow up report for this corrected information.Correcting udi # from (b)(4).This is a follow up report for this corrected information.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ANK STAND C/ ABUT B/3/4STRAI
Common Device Name
IMPLANT, ENDOSSEOUS, ROOT-FORM
Manufacturer (Section D)
DENTSPLY IMPLANTS MANUFACTURING GMBH
rodenbacher chaussee 4
hanau hessen 63457
GM  63457
Manufacturer (Section G)
DENTSPLY IMPLANTS MANUFACTURING GMBH
rodenbacher chaussee 4
hanau hessen 63457
GM   63457
Manufacturer Contact
dan eagar
221 west philadelphia st.
york, PA 17401
7178457511
MDR Report Key19905635
Report Number3013111692-2024-23567
Device Sequence Number7174018
Product Code DZE
UDI-Device Identifier07392532215285
UDI-Public07392532215285
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K041509
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2017
Device Explanted Year2023
Reporter Type Manufacturer
Report Source Foreign,Health Professional
Initial Reporter Occupation Dentist
Type of Report Initial,Followup
Report Date (Section B) 08/22/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Catalogue Number31021110
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Distributor Facility Aware Date07/24/2024
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 07/24/2024
Supplement Date Received by ManufacturerNot provided
Initial Report FDA Received Date08/05/2024
Supplement Report FDA Received Date08/22/2024
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Usage of Device A
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
31010428*1 IMPLANT ANKYLOS
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-