The reported event was unconfirmed because the reported failure could not be reproduced.The product had not caused the reported failure.No root cause could be found because the reported event was unconfirmed.A potential root cause for this failure mode could be torn rubberize that causing leak.A review of the device history record did not show any problems or conditions that would have contributed to the reported issue.The instructions for use were found adequate and state the following: indication for use: this device is an indwelling catheter in the bladder for urinary drainage.Precautions: 1.Precaution for use natural rubber may cause allergic symptoms including itching, redness, urticaria, swelling, fever, dyspnea, asthma-like symptoms, decrease blood pressure, shock, etc.When such symptoms appear use of the devise should be stopped immediately and consult the attending physician so that appropriate measures should be taken.2.Important precaution product is sterile unless package is opened or damaged.This device is for urological use only.Do not use for other purposes, the law restricts this device to sale by or on the order of a physician.When abnormal resistance is encountered in inserting catheter, do not use excessive force and remove the catheter to find out the cause of difficulties in insertion.When inflating or deflating balloon with sterile water, use a luer tip (needleless) syringe.Don does not use a needle.Visually inspect the product for any imperfection or surface deterioration prior to use.Do not sterilize.Use this device immediately after opening the package.After use, handle and dispose of in accordance with acceptance medical practice.Do not aspirate urine through drainage funnel wall.This may cause malfunction of catheter, or urinary tract infection.Since movement of the body may twist or bend catheter to cause occlusion, care should be taken to fix the catheter securely.When urinary flow cannot be noted, confirm that the catheter is nether occluded nor broken.To deflate the balloon and remove catheter, gently aspiration to encourage deflation if needed.After balloon deflation withdraw the catheter at room temperature away from direct exposure to light.Inspect packaging prior to use.If packaging is opened or damage do not used.Capped adapter attached to irrigation lumen is designed to connect catheter with bladder irrigation line or tube.While in use, open the cap and attached irrigation lumen tube to it.After use cleanse the opening of lumen and close the cap.Always use aseptic technique following physician direction while using irrigation lumen.This report references a us equivalent device.The us udi equivalent for this product number is used.H11: section a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
|
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.H11: section a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|