• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: SHIRAKAWA OLYMPUS CO., LTD. VISERA RHINO-LARYNGO VIDEOSCOPE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SHIRAKAWA OLYMPUS CO., LTD. VISERA RHINO-LARYNGO VIDEOSCOPE Back to Search Results
Model Number ENF-V2
Medical Device Problem Code Device Reprocessing Problem (1091)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
E1/establishment name: (b)(6) hospital.The evaluation of the event is ongoing.Should additional relevant information become available, a supplemental report will be submitted.
 
Event or Problem Description
It was reported that during a patient's visit to an ent (ear nose and throat) outpatient clinic, a rhino-laryngo videoscope (enf-v2 or enf-v3) was used for an unspecified diagnostic procedure and then cleaned with the endoscope reprocessor (oer-4).The same patient returned two weeks later for a diagnostic colonoscopy procedure using the colonovideoscope (pcf-h290zi), which was also cleaned with oer-4.It was subsequently reported the patient had creutzfeldt-jakob disease.At this time, it is unknown when the patient was diagnosed, however; it was discovered after the use of the olympus devices.Both scopes were used more than 20 times by other patients.There were no other confirmed creutzfeldt-jakob disease (cjd) infections at this time.This complaint is for the subsequent patient that used the device after the reprocessing.The procedure was completed using the same set of equipment.There were no reports of patient harm.
 
Additional Manufacturer Narrative
Correction: g2: 29 jul 2024.This supplemental report is being submitted to provide the results of the legal manufacturer's final investigation.Despite good faith efforts attempts made, no additional information was obtained.A review of the device history record found no deviations that could have caused or contributed to the reported issue.Based on the results of the investigation, and because the subject device was not returned, the reported event could not be confirmed, and a definitive root cause could not be determined.Olympus will continue to monitor the field performance of this device.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VISERA RHINO-LARYNGO VIDEOSCOPE
Common Device Name
RHINO-LARYNGO VIDEOSCOPE
Manufacturer (Section D)
SHIRAKAWA OLYMPUS CO., LTD.
3-1 okamiyama
odakura, nishigo-mura,
nishishirakawa-gun, fukushima 961-8 061
JA  961-8061
Manufacturer (Section G)
SHIRAKAWA OLYMPUS CO., LTD.
3-1 okamiyama
odakura, nishigo-mura,
nishishirakawa-gun, fukushima
Manufacturer Contact
todd brill
800 west park drive
westborough, MA 01581
5082077661
MDR Report Key20049540
Report Number3002808148-2024-08004
Device Sequence Number7977720
Product Code EOB
UDI-Device Identifier04953170291029
UDI-Public04953170291029
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K061313
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 08/30/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberENF-V2
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/28/2024
Supplement Date Received by Manufacturer08/29/2024
Initial Report FDA Received Date08/23/2024
Supplement Report FDA Received Date08/30/2024
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured04/05/2012
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Reuse
Patient Sequence Number1
Patient SexUnknown
-
-