Z-SYSTEMS AG Z5; ENDOUSSEOUS DENTAL IMPLANT ROOT FORM Back to Search Results
Model Number Z5C-40-10
Medical Device Problem Code Loss of Osseointegration (2408)
Health Effect - Clinical Code Unspecified Tissue Injury (4559)
Date of Event 03/27/2024
Type of Reportable Event Serious Injury
Event or Problem Description
Loss of osseointegration due to bruxism.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
Z5
Common Device Name
ENDOUSSEOUS DENTAL IMPLANT ROOT FORM
Manufacturer (Section D)
Z-SYSTEMS AG
werkhofstrasse 5
oensingen, 4702
SZ  4702
Manufacturer (Section G)
Z-SYSTEMS AG
werkhofstrasse 5
oensingen, solothurn 4702
SZ   4702
Manufacturer Contact
stephan kyburz
werkhofstrasse 5
oensingen, 4702
SZ   4702
MDR Report Key20065126
Report Number3006948427-2024-00178
Device Sequence Number7728770
Product Code DZE
UDI-Device Identifier07640166760412
UDI-Public07640166760412
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
K132881
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2023
Device Explanted Year2024
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Dentist
Remedial Action Replace
Type of Report Initial
Report Date (Section B) 08/26/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date10/31/2023
Device Model NumberZ5C-40-10
Device Catalogue NumberZ5C-40-10
Device Lot Number17424
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/26/2024
Initial Report FDA Received Date08/26/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured10/31/2018
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Disability;
Patient Age71 YR
Patient SexMale
-
-