EXACTECH, INC. NV GXL LNR, +5LAT, 36MM G3-56/58MM CUPS; PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, CEMENTED
|
Back to Search Results |
|
| Catalog Number |
136-36-53 |
| Medical Device Problem Codes |
Unstable (1667); Naturally Worn (2988)
|
| Health Effect - Clinical Codes |
Pain (1994); Discomfort (2330); Osteolysis (2377); Ambulation or Postural Difficulties (2544); Balance Problems (4401); Joint Laxity (4526)
|
| Date of Event |
01/10/2024
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported that approximately 103 months after a right hip replacement procedure, the patient underwent a revision procedure to address prosthesis wear, and acetabular osteolysis.No further issues or complications were reported.No additional information is available.
|
| |
|
Additional Manufacturer Narrative
|
|
D10: concomitant products: (b)(6), - 142-36-10 - cocr fem head 36mm +10 offset 12/14.(b)(6), - 164-02-16 - element-stem, collarless w/ha, high offset, sz 16.(b)(6), - 186-01-58 - integrip cc, cluster 58mm, g3.The device was not returned for evaluation and no medical or other records containing treatment information or patient information have been received; therefore, the reported event cannot be confirmed, nor can the circumstances or potential causes or contributors to the alleged event be evaluated.Should additional, material information become available that permits more analysis or conclusions, a supplemental report will be filed accordingly.
|
| |
|
Additional Manufacturer Narrative
|
|
H6: corrected health effect - clinical code, medical device problem code, type of investigation.The most likely cause for the reported revision due to prosthesis wear and instability is a combination of the risk factors specified such as use error, implant positioning, implant size selection, and patient factors (fitness for surgery, biomechanics, activity level and local tissue oxidation potential).Additionally, the sequence of events as related to the reported wear and instability cannot be confirmed and the contributions of each to the reported event cannot be determined.However, this cannot be confirmed as the devices were not returned for evaluation, and images and radiographs were not provided.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional and/or corrected information.The following sections were corrected: h6.If any further information is obtained that would change or alter any information provided, a supplemental report will be filed accordingly.".
|
| |
|